Pump On Ended with Cycle Switch Activation

A B

C D

E

FIG. 58

If the Pump On sequence has been programmed to end by a Cycle Switch Activation:

The GLC 4400 pump output relay activates (J7-3) and will stay on until the correct number of cycle switch closures is received (J6-3) (see Setup Menus, Cycle End Setup page 19).

The Pump On LED (A) remains on during this time.

The Pump On (C) icon displays.

The Cycle LED (B) and Cycle Count Mode icon (D) display indicating the cycle switch is activated.

The cycle indicator bar (E) displays a visual repre- sentation of the cycle switch closures received.

If the set number of cycle switch closures is not received before time expires, an alarm occurs.

Run Mode

Pump Off Ended with Time

D

A

C

FIG. 59

If the Pump Off sequence has been programmed to be ended by TIME:

The GLC 4400 pump output relay activates (J7-3) and will stay off until the time expires. (see Setup Menus, Pump Off, page 20).

The Pump On LED (A) remains off during this time.

The Pump Off icon (C) displays.

The Timer Mode icon (D) displays and indicates the Timer Mode.

Pump Off Ended with Machine Counts

B

A

CD

FIG. 60

If the Pump Off sequence has been programmed to be ended by MACHINE COUNTS:

313855H

31

Page 31
Image 31
Graco 24B591 Pump On Ended with Cycle Switch Activation, Pump Off Ended with Time, Pump Off Ended with Machine Counts