Graco 24B596, 24B591 Prelube Power Up, Pump On Ended with Pressure, Pump On Ended with Time

Models: 24B591 24B596

1 36
Download 36 pages 32.94 Kb
Page 30
Image 30

Run Mode

Prelube Power Up

The Timer icon (D) displays and indicates the Timer Mode.

Pump On Ended with Pressure

FIG. 55

If Prelube is enabled (page 22), the programmed pre- lube sequence occurs.

If no Prelube sequence has been selected, the lube cycle that was in progress at power down is resumed.

A

C

FIG. 57

B

D

Pump On Ended with Time

A D

C

FIG. 56

If the Pump On sequence has been programmed to be ended by TIME:

The GLC 4400 pump output relay activates (J7-3) and will stay on until the time expires. (see Setup Menus, Pump On, page 18).

The Pump On LED (A) remains on during this time.

The Pump On (C) icon displays.

If the Pump On sequence has been programmed to end by a pressure switch:

The GLC 4400 pump output relay activates (J7-3) and will stay on until a switch closure is received (J6-3) (see Setup Menus, Pump On, page 19).

The Pump On LED (A) remains on during this time.

The Pump On (C) icon displays.

The Cycle LED (B) illuminates and Pressure Mode icon (D) displays to indicate the pressure switch.

If the pressure switch closure is not received before time expires, an alarm occurs.

NOTE: If Pump On is ended by a pressure switch and no Power Up delay is selected, when power to the GLC 4400 is turned on, the GLC 4400 starts at the beginning of the Pump On time instead of resuming the Pump On time where it left off.