Run Mode

Run Mode

When you first turn the Lubrication Controller power on, the identification screen shown in FIG. 53 displays.

A

C D

A

B

C

D

FIG. 53

B

 

FIG. 54

 

 

 

 

 

 

 

 

 

ADisplay Contrast Adjustment: UP and DOWN Arrows can be used to adjust the display contrast.

BBacklight Brightness Adjustment: LEFT and RIGHT Arrows can be used to adjust the backlight brightness.

NOTE: Contrast and Brightness adjustments can be made on any Run Screen at any time.

CSoftware (Part Number): 15Y354

D(Software) Version: 1.01.XX

Screen Identification

The following screen is only shown as an example of the information that is displayed on a Run screen. A com- plete description of the icons and symbols shown in FIG. 54 is provided on page 3.

AOperating Mode Identification - Sets up Pump On/ Pump Off, page 22.

BTime Counter - Actual elapsed time counts down while the pump runs - set up in Pump On Setup, page 18.

CProgression Bar - Real-time, visual representation of the elapsed time the pump has been on. Runs in conjunction with B.

DTotal Pump On Time - Shows the total amount of time the pump is on. Setup on the Pump On setup screen, page 18.

313855H

29

Page 29
Image 29
Graco 24B591, 24B596 important safety instructions Run Mode, Screen Identification