Desa VGL24PRA, VGL24NRA Optional HAND-HELD Remote Operation, Thermostat Series Model, Ghrctb

Page 21

OPERATING HEATER

Continued

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, pages 29). Follow instructions included with the re- mote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 19.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 30). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

THERMOSTAT SERIES (MODEL

GHRCTB)

 

The hand-held remote can be operated using

either the manual mode (MANU) or thermo-

static mode (AUTO) (see Figure 32). To select

Fahrenheit/Centigrade mode display, carefully

press the ˚C/˚F mode button with the end of a

paper clip or similar blunt object.

Digital

Turns Hand-

Display

Held Remote

Shows

On or Off and

Temperature

Allows You

and Settings

to Choose

 

the Manual

Turns

Setting

Burners On

 

or Off

Selects Auto

 

Setting

Flame Adjustment

Control Knob in Knob

On Position

 

F

PIL

 

 

 

 

 

 

OT

H

 

 

 

 

O

F

 

 

 

 

 

 

O

I

O

REMOTE

OFF

ON

 

 

N

 

 

 

 

 

L

 

 

 

Selector Switch in Remote Position

Decreases

Room

 

Temperature

in AUTO

 

Mode

Locks System to

 

 

Prevent Accidental

 

Ignition

Increases

Room

Temperature

in AUTO

Mode

Figure 30 - Setting the Selector Switch,

Control Knob, and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 31).

Control Button

Turns Burners

On and Off

Figure 31 - On/Off Hand-Held Remote Control Unit (GHRCB)

Figure 32 - Thermostat Hand-Held Remote Control Unit (GHRCTB)

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by press- ing the TEMP + or - buttons.

112882-01B

www.desatech.com

21

Image 21
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Remote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionAIR for Combustion Ventilatioin Ventilation AIRVentilation Air From Inside Building Ventilation Air From Outdoors InstallationLog Size Side Wall Ceiling Check GAS TypeMinimum Firebox Size LogDetermining Minimum Mantel Clearances When Using a Hood Mantel ClearancesMinimum Noncombustible Material Clearances Minimum Mantel Clearances Without Using Hood Floor Clearances Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Equipment Shutoff Valve Installing Optional Remote AccessoriesConnecting Wires Log #1 Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Series Model Optional HAND-HELD Remote OperationGhrctb ON/OFF Series Model GhrcbInspecting Burners Auto Shutoff FeaturePilot Flame Pattern Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Moisture/condensation noticed Statement above Gas leak. See WarningReplacement Parts Wiring DiagramService Hints Technical ServiceReceiver and HAND-HELD Remote Control KIT Ghrcb Series Cleaning KIT CCKInformation Video Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters