Desa VGL24PRA, VGL24NRA, VGL18PRA, VGL30NRA installation manual Connecting Wires

Page 17

INSTALLATION

Continued

8.Install remote receiver into receiver bracket using pads and push button clips provided with receiver (see Figure 20).

9.Connect wires to control valve at the TPTH and TH locations as shown in Figure 21. Note: Make sure excess wire does not interfere with burner or pilot.

10.If heater was removed from fireplace before installation of remote accessory, see Installing Heater Base Assembly on page 13 to reinstall heater into fireplace. Test gas connection for leaks (see Checking Gas Connections, pages 15 and 16).

11.If logs were removed from heater for install remote accessory, replace logs (see Installing Logs, pages 18 and 19).

9-Volt Battery

Battery

Clip

Bracket

Pad

Terminal

Push Button

 

 

Wires

Clips

 

 

 

Figure 20 - Installing Remote Receiver

White Wire

From Receiver

Control

Valve

Red Wire From

Receiver

Figure 21 - Connecting Wires

Installing Batteries for Remote Receiver and Hand Held Remote Control Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand- held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver behind receiver bracket mounted on base assembly.

2.Locate the battery clip mounted on the back of the receiver (see Figure 20).

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Installing 9-Volt Battery (Not Included) in Hand- Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the battery housing.

Terminal

Battery Cover

 

Wires

 

 

 

 

Remote

 

 

 

Control

9-Volt

 

Battery

Unit

 

 

Battery

 

 

 

Housing

 

 

 

 

Figure 22 - Installing Battery in Hand-

Held Remote Control Unit (CGHRCB

 

Series)

 

 

 

Remote

 

Terminal

Control Unit

 

 

 

9-Volt

Wires

 

 

 

 

 

Battery

 

 

 

 

 

 

Battery

Battery

 

 

Cover

 

 

 

Housing

 

 

 

Figure 23 - Installing Battery in Hand-

Held Remote Control Unit (CGHRCTB

 

Series)

 

112882-01B

www.desatech.com

17

Image 17
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Remote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Inside Building AIR for Combustion VentilatioinVentilation AIR Ventilation Air From Outdoors InstallationLog Size Side Wall Ceiling Check GAS TypeMinimum Firebox Size LogMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearances When Using a HoodMantel Clearances Minimum Mantel Clearances Without Using Hood Floor Clearances Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base Assembly External Regulator With Vent Pointing Down Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Equipment Shutoff Valve Installing Optional Remote AccessoriesConnecting Wires Log #1 Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Series Model Optional HAND-HELD Remote OperationGhrctb ON/OFF Series Model GhrcbInspecting Burners Auto Shutoff FeaturePilot Flame Pattern Main BurnerLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Moisture/condensation noticed Statement above Gas leak. See WarningReplacement Parts Wiring DiagramService Hints Technical ServiceReceiver and HAND-HELD Remote Control KIT Ghrcb Series Cleaning KIT CCKInformation Video Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty