Desa GWP30TA, GWP20TA, GWN30TA, GWN20TA Troubleshooting, Observed Problem Possible Cause Remedy

Page 19

Troubleshooting

WARNING:Turnoffandunplugheaterandletcoolbeforeservicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

When ignitor button is pressed,

1. Ignitor electrode positioned

1.

Replace pilot assembly

there is no spark at ODS/

 

wrong

 

 

pilot

2. Ignitor electrode broken

2.

Replace pilot assembly

 

3.

Ignitor electrode not con-

3.

Reconnect ignitor cable

 

 

nected to ignitor cable

 

 

 

4.

Ignitor cable pinched or

4.

Free ignitor cable if pinched

 

 

wet

 

by any metal or tubing.

 

 

 

 

Keep ignitor cable dry

 

5.

Broken ignitor cable

5.

Replace ignitor cable

 

6.

Bad piezo ignitor

6.

Replace piezo ignitor

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or

1.

Turn on gas supply or open

there is spark at ODS/pilot but

 

equipment shutoff valve

 

equipment shutoff valve

no ignition

 

closed

 

 

 

2.

Control knob not in PILOT

2.

Turn control knob to PILOT

 

 

position

 

position

 

3.

Control knob not pressed in

3.

Press in control knob while

 

 

while in PILOT position

 

in PILOT position

 

4.

Air in gas lines when in-

4.

Continue holding down

 

 

stalled

 

control knob. Repeat ignit-

 

 

 

 

ing operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply (pro-

5.

Contact local propane/LP

 

 

pane/LP gas only)

 

gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Clean-

 

 

 

 

ing and Maintenance, page

 

 

 

 

18) or replace ODS/pilot

 

 

 

 

assembly

 

7.

Gas regulator setting is not

7.

Replace gas regulator

 

 

correct

 

 

119344-01B

www.desatech.com

19

Image 19
Contents Models GWN20TA, GWP20TA, GWN30TA, GWP30TA, WMN20a, WMP20a What to do if YOU Smell GASSafety Information Table of ContentsSafety Information Unpacking Safety InformationProduct Features Local CodesConfined and Unconfined Space Air For Combustion VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Check GAS TypeThis heater is designed to be mounted on a wall InstallationInstallation Items Locating HeaterInstalling Heater to Wall Attaching To Wall Anchor Method 30,000 Btu/Hr Models20,000 Btu/Hr Models Attaching To Wall Stud MethodMounting Base Feet to Heater Installing Bottom Mounting ScrewsMounting heater to floor With optional floor kit Heater WallTypical Inlet Pipe Diameters Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsCorrect all leaks at once Pressure Testing Heater Gas ConnectionsDo not try to light any appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsThermostat Control Operation Manual Lighting ProcedureOperating Heater To Turn OFF GAS To AppliancePilot Flame Pattern Inspecting HeaterBurner Flame Pattern Cabinet Cleaning MaintenanceODS/PILOT and Burner Burner Pilot Air InletObserved Problem Possible Cause Remedy TroubleshootingTroubleshooting Burner orifice Observe minimum installaSlight smoke or odor during BlockedStatement above Gas leak. See WarningTechnical Service SpecificationsService Hints Replacement PartsModels WMN20A, WMP20A, GWN20TA, GWP20TA, GWN30TA and GWP30TA Illustrated Parts BreakdownNJF 8C Parts ListElectronic ignitor Kit GA435 Not Shown AccessoriesEquipment Shutoff Valve GA5010 Base Kit GA4550Parts Centrals Industrial Drive P.O. Box 119344-01 Rev. B Warranty InformationKeep this Warranty Model Serial No Date of Purchase