Desa WMP20A, GWP20TA Operating Heater, To Turn OFF GAS To Appliance, Thermostat Control Operation

Page 16

OPERATING HEATER

Continued

WARNING: Always operate manual control heaters at the locked positions. Operation between these positions may create a possible health hazard if used in a poorly ventilated room. Read owner’s manual for complete instructions.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 21 - Pilot (actual pilot may vary)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. Selecting the 5 setting will cause the burner to remain fully on without modulating down in most cases.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 9).

2.Follow steps 1 through 7 under Lighting Instructions, page 15.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, under Lighting Instructions, page 15.

5.Replace front panel.

16

www.desatech.com

119344-01B

Image 16
Contents What to do if YOU Smell GAS Models GWN20TA, GWP20TA, GWN30TA, GWP30TA, WMN20a, WMP20aTable of Contents Safety InformationSafety Information Safety Information Product FeaturesLocal Codes UnpackingAir For Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Installation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Installation ItemsLocating Heater This heater is designed to be mounted on a wallInstalling Heater to Wall 30,000 Btu/Hr Models 20,000 Btu/Hr ModelsAttaching To Wall Stud Method Attaching To Wall Anchor MethodInstalling Bottom Mounting Screws Mounting heater to floor With optional floor kitHeater Wall Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Heater Gas Connections Correct all leaks at onceFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Do not try to light any applianceManual Lighting Procedure Operating HeaterTo Turn OFF GAS To Appliance Thermostat Control OperationPilot Flame Pattern Inspecting HeaterBurner Flame Pattern Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot Air Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Observe minimum installa Slight smoke or odor duringBlocked Burner orificeGas leak. See Warning Statement aboveSpecifications Service HintsReplacement Parts Technical ServiceIllustrated Parts Breakdown Models WMN20A, WMP20A, GWN20TA, GWP20TA, GWN30TA and GWP30TAParts List NJF 8CAccessories Equipment Shutoff Valve GA5010Base Kit GA4550 Electronic ignitor Kit GA435 Not ShownParts Centrals Warranty Information Keep this WarrantyModel Serial No Date of Purchase Industrial Drive P.O. Box 119344-01 Rev. B