Desa GWN30TA, GWP20TA, GWP30TA, GWN20TA, WMP20A, WMN20A installation manual Troubleshooting

Page 20

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully

1.

Press in control knob fully

goes out when control knob

 

pressed in

 

 

is released

2. Control knob not pressed in

2.

After ODS/pilot lights, keep

 

 

long enough

 

control knob pressed in 30

 

 

 

 

seconds

 

3.

Safety interlock system has

3.

Wait one minute for safety

 

 

been triggered

 

interlock system to reset.

 

 

 

 

Repeat ignition operation

 

4.

Equipment shutoff valve not

4.

Fully open equipment shut-

 

 

fully open

 

off valve

 

5.

Thermocouple connection

5.

Hand tighten until snug,

 

 

loose at control valve

 

then tighten 1/4 turn more

 

6.

Pilot flame not touching

6.

A) Contact local natural or

 

 

thermocouple, which al-

 

propane/LP gas company

 

 

lows thermocouple to cool,

 

 

 

 

causing pilot flame to go

 

B) Clean ODS/pilot (see

 

 

out. This problem could be

 

Cleaning and Maintenance,

 

 

caused by one or both of

 

page 18) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

 

 

 

 

Burner does not light after

1. Burner orifice is clogged

1.

Clean burner (see Cleaning

ODS/pilot is lit

 

 

 

and Maintenance, page 18)

 

 

 

 

or replace burner orifice

 

2.

Inlet gas pressure is too

2.

Contact local natural or

 

 

low

 

propane/LP gas company

 

 

 

 

Delayed ignition of burner

1. Manifold pressure is too

1.

Contact local natural or

 

 

low

 

propane/LP gas company

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 18)

 

 

 

 

or replace burner orifice

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 18)

 

 

 

 

or replace burner orifice

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

20

www.desatech.com

119344-01B

Image 20
Contents What to do if YOU Smell GAS Models GWN20TA, GWP20TA, GWN30TA, GWP30TA, WMN20a, WMP20aTable of Contents Safety InformationSafety Information Safety Information Product FeaturesLocal Codes UnpackingAir For Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Installation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Installation ItemsLocating Heater This heater is designed to be mounted on a wallInstalling Heater to Wall 30,000 Btu/Hr Models 20,000 Btu/Hr ModelsAttaching To Wall Stud Method Attaching To Wall Anchor MethodInstalling Bottom Mounting Screws Mounting heater to floor With optional floor kitHeater Wall Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Heater Gas Connections Correct all leaks at onceFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Do not try to light any applianceManual Lighting Procedure Operating HeaterTo Turn OFF GAS To Appliance Thermostat Control OperationBurner Flame Pattern Inspecting HeaterPilot Flame Pattern Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot Air Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Observe minimum installa Slight smoke or odor duringBlocked Burner orificeGas leak. See Warning Statement aboveSpecifications Service HintsReplacement Parts Technical ServiceIllustrated Parts Breakdown Models WMN20A, WMP20A, GWN20TA, GWP20TA, GWN30TA and GWP30TAParts List NJF 8CAccessories Equipment Shutoff Valve GA5010Base Kit GA4550 Electronic ignitor Kit GA435 Not ShownParts Centrals Warranty Information Keep this WarrantyModel Serial No Date of Purchase Industrial Drive P.O. Box 119344-01 Rev. B