TROUBLESHOOTING

WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts

1.

Wrong pump pressure

1.

See Pump Pressure

off heater after a short period of time.

 

 

 

Adjustment, page 10.

 

2.

Dirty air output, air intake, and lint filters

2.

See Air Output, Air Intake and Lint Fil-

 

 

 

 

ters, page 10.

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 8.

 

4.

Dirt in nozzle

4.

See Nozzle, page 11.

 

5.

Dirty photocell lens

5.

Clean photocell lens.

 

6.

Bad flame-out control

6.

Replace flame-out control.

 

 

 

 

 

Heater will not ignite, but motor runs for a

1.

Wrong pump pressure

1.

See Pump Pressure Adjustment, page 10.

short period of time.

2.

Carbon deposits on spark plug and/or

2.

See Spark Plug, page 9.

 

 

improper gap

 

 

 

3.

Dirty fuel filter

3.

See Fuel Filter, page 8.

 

4.

Dirt in nozzle

4.

See Nozzle, page 11.

 

5.

Water in fuel tank

5.

Drain and flush fuel tank with clean

 

 

 

 

kerosene. See Storing, Transporting, or

 

 

 

 

Shipping, page 6.

WARNING: High voltage!

6.Electronic ignitor not grounded (earthed)

7.Bad electronic ignitor

6.Make sure electronic ignitor mounting is tight.

7.Replace electronic ignitor.

Motor does not start when heater is plugged 1.

Flame-out control not reset

in, fan rotates slowly or does not turn.

 

2.

Binding pump rotor

1.Reset flame-out control button, see Fig- ures 5 and 6, page 5.

2.If fan is hard to turn, see Pump Rotor, page 12.

104468

7

Image 7
Contents Portable Forced AIR Heaters Portable Forced AIR Heaters Safety InformationUnpacking Product Identification For 100,000 and 150,000 BTU/HR Models only Assembly Fuels VentilationTo Stop Heater Extension Cord Wire Size RequirementsTheory Operation To Start HeaterHow Often How To Preventative MaintenanceStoring TRANSPORTING, or Shipping ScheduleObserved Fault Possible Cause Remedy Troubleshooting35/70,000 Btu/Hr Models Service ProceduresUpper Shell Removal Fuel Filter70/100,000 Btu/Hr Models Spark Plug35,000 Btu/Hr Model 70/100/150,000 Btu/Hr ModelsAir Output, Air Intake, and Lint Filters Pump Pressure AdjustmentModel Removing Air and Fuel Line Hoses, 35,000 Btu/Hr Model NozzlePump Rotor Procedure if rotor is bindingWiring Diagrams SpecificationsFan 35,000 BTU/HR Illustrated Parts BreakdownKEY Part Number Description QTY Parts List70,000 BTU/HR Burner Head AssemblyWLE-3 100,000 BTU/HR Lock Washer, #10 M27417 Drain Plug 150,000 BTU/HR Lock Washer, #10 099229-01 Photocell Bracket 100,000 and 150,000 BTU/HR Models Wheels Handles100,000 150,000 AIR Gauge KIT HA1180 AccessoriesCorporate Headquarters Warranty and Repair ServiceCalentadores Portatiles DE Aire Forzado Informacion DE Seguridad Calentadores Portatiles DE Aire ForzadoDesembalaje Identificacion DEL ProductoSólo Para Modelos DE 29,3 Y 44 KW 100.000 Y 150.000 BTU/HR ArmadoCombustibles VentilacionFuncionamiento Teoria DE FuncionamientoIntervalo Procedimiento Almacenamiento Programa DETransporte O Mantenimiento Embarque PreventivoAdvertencia ¡Alto voltaje Localizacion DE AveriasModelos de 10,2/20,5 kW 35.000/ 70.000 Btu/hr Procedimientos DE ServicioRemoción del casco superior Filtro de combustible20,5/29,3 kW 70/100.000 Btu/hr Modelos BujíaModelo de 10,2 kW 35,000 Btu/hr Modelos de 20,5/29,3/44 kW 70.000/ 100.000/150.000 Btu/hrAjuste de la presión de la bomba Filtros de salida de aire, de admisión de aire y de pelusaModelo de 10,2 kW 35.000 Btu/hr BoquillaProcedimiento si el rotor se atasca Rotor de la bombaEspecificaciones Diagramas DE AlambradoVentilador 10,2 KW 35.000 BTU/HR Despiece IlustradoClave NO. Pieza Descripcion Cant Lista DE PiezasConjunto del quemador 20,5 KW 70.000 BTU/HR10-3 M10809-1 29,3 KW 100.000 BTU/HR Arandela #10 cerrandura HA3019 Conjunto de fotocélula 44 KW 150.000 BTU/HR Arandela, #10 Cerrandura 098512-36 Cámara de combustión 29,3 Y 44 KW 100.000 Y 150.000 BTU/HR Ruedas Y Asas Para Modelos DEJuego DE Ruedas Y ASA DE Servicio Severo HA1202 AccesoriosDesa