Master Lock XR20 manual Home/Away System Arming, Arming a Home/Away System

Page 15

Home/Away System Arming

Area Assignment: Your security system is divided into two or three separate areas. Motion detectors, inside doors, and other interior devices are assigned to an Interior and possibly Bedroom area while windows and exterior doors, are assigned to a Perimeter area.

Arming the system: When arming a Home/Away system, the keypad displays HOME AWAY or HOME SLEEP AWAY. If you select AWAY, you arm all areas of the system. You will want to arm all areas when leaving with nobody staying inside. Selecting HOME arms only the Perimeter of the system. Perimeter arming is for when you are staying inside but want the comfort of knowing the exterior doors and windows are armed. Selecting SLEEP arms the Perimeter and Interior devices but leaves devices near bedrooms and other nighttime areas off.

System Ready/System Not Ready Keypad Displays

When all zones in the system are in a normal condition and can be armed without bypassing, the keypad displays SYSTEM READY. If there are one or more zones that are not in a normal condition, the keypad displays SYSTEM NOT READY. Pressing any top row Select key during this display shows the bad zone name.

Arming a Home/Away System

1. Enter your user code. The keypad displays HOME AWAY or HOME SLEEP AWAY (you may have three areas).

2.Select HOME to arm the Perimeter only.

3.Select SLEEP to arm the Perimeter and Interior.

4.Select AWAY to arm the Perimeter, Interior, and Bedroom.

5.The keypad displays zones that have been bypassed prior to arming and 24-hour zones that are in a bad condition. No action is required by you.

6.At this point you can force arm or bypass any bad zones. A zone that is force armed will be restored into the system if it later returns to normal. A zone that is bypassed will remain bypassed until the system is disarmed. See steps 6a through 6d.

6a. If a problem exists on any zones, the zone name and problem are shown followed by: OKAY BYPASS STOP.

6b. Select OKAY to force arm the zone(s) before arming.

6c. Select BYPASS to bypass the zone(s) before arming.

6d. Select STOP to stop the system from arming. Correct the zone problem(s) and return to step 1.

7.The keypad displays PERIMETER ON if you selected HOME, or PERIM/INT ON if you selected SLEEP, or ALL SYSTEM ON if you selected AWAY.

8.The keypad next displays EXIT: ## INSTNT and begins to count down the number of seconds remaining for you to exit. The keypad will sound the exit delay alert when 20 seconds remain, and when the delay expires, all zones are armed.

9.You can select INSTNT while EXIT: ## INSTNT is displayed to immediately arm all zones and make them instant. The keypad displays INSTANT.

10.When the system is fully armed, the keypad displays PERIMETER ON for Perimeter arming, PERIM/INT ON for Perimeter and Interior arming, and ALL SYSTEM ON for all areas armed.

XR20 Arming and Disarming

11

Image 15
Contents XR20 Area Systems All/Perimeter and Home/Away SystemsSecurity Command Users Guide Practice your escape plans Decide where to meetDraw a floorplan of your home or business Develop escape routesTest Your System Weekly Security Command keypadAbout Your Security System Parts of the SystemSecurity Command Keypad Character Keypad User Options MenuSelect keys Special Security Command Messages Special Security Command TonesSystem Trouble or Service Required Understanding Security System Terms Armed Status Exit ErrorCentral Station Monitoring StatusArming Functions How your System OperatesArea System Arming Arming the SystemExample Office no YES Disarming an Area System Area System DisarmingArming an All/Perimeter System All/Perimeter System ArmingSystem Ready/System Not Ready Keypad Displays Instant ArmingDisarming During an Alarm All/Perimeter System DisarmingDisarming an All/Perimeter System Arming a Home/Away System Home/Away System ArmingEasy Exit Feature Home/Away System DisarmingDisarming a Home/Away System Menu Option Description Security Command User MenuTo access the User Menu User Menu OptionsSelecting Zone Activity Check User Check-inZone Activity Check Sending a Check-in ReportOutputs On Off Sensor ResetResetting the Sensors Enter your user code to reset sensorsUsing the Bypass Zones Function Bypass ZonesZone Monitor Using the Zone Monitor Function Using the System Test FunctionSystem Test User Codes User Code Authority LevelsAdding User codes Changing User codes 6a. Temp Code no YES6c. ARM only no YES Deleting User codes Setting an Arming and Disarming ScheduleAmbush Codes SchedulesExtending a Closing Schedule Setting the Date and TimeExtended Schedules Date and TimeUsing the Display Events Function Display EventsZone Activity Check Event Display BYP Bypass RST Restore Zone Bypass Event DisplaysZone Event Displays User Check-in Event Displays Arming and Disarming Event DisplaysStation at the date and time shown User Code Change Event DisplaysSupervisory Event Displays Test report was sent on OctSystem Monitor Event Types There are 2 event types Service Request?System Monitor Event Displays An AC failure occurred at 105 AMSystem Setup Protection AreasOutputs HOW to Fill in this HOW to Fill in this Easy Entry Users Guide AppendixArming and Disarming AN ALL/PERIMETER System Disarming a Home/Away or All/Perimeter System Using the Alert ButtonsFA113 Users Guide Arming a Home/Away or All/Perimeter SystemArea Name Pager Direct Users GuideArea Names Pager DirectAlphanumeric Pager Display Numeric Pager DisplayPhoneAccess Users Guide You will hearPress To do this You will hear Voice Module Common Keypad Displays Message Meaning Possible SolutionsIndex This page has been intentionally left blank LT-0303 5/02