PhoneAccess™ Quick Commands
Quick Reference Wallet Card

PhoneAccess™ User's Guide

This exciting feature allows you to call your XR20 system from any outside touch-tone phone to arm and disarm protection areas or turn on or off the panel's relay outputs.

How it works

1.From a touchtone phone, call the XR20 system's phone number.

2.The XR20 answers and sounds a short ready tone. You now have 8 seconds to enter a valid Master user code. If the user code is accepted by the panel, you will hear one or more beeps giving you the current armed status of the system. (You can also find out the armed status of the system by pressing the * key at any time.)

If

You will hear

All areas are armed

3 short beeps

Area 1 (Perimeter) is armed

1 short beep

Any area is armed

2 short beeps

All areas are disarmed

1 long beep

If the user code is not accepted by the panel, you will hear four short beeps. Check the user code and try again. After 3 unsuccessful attempts to enter the code, the panel locks out PhoneAccess™ until a valid user code is entered at a keypad.

3.Once the user code is accepted by the panel and the armed status is given, you can enter the following commands:

Press

To do this

You will hear

#, 1

Arm all areas

3 short beeps

#, 2

Arm area 1

1 short beep

#, 3

Arm areas 1 & 2

2 short beeps

#, 0

Disarm all areas*

1 long beep

#, 5, 4, 0, n*

Toggles the output

1 short beep = on

(* Use outputs 1, 2, 3, or 4 in place of n)

1 long beep = off

 

 

4 short beeps = restricted

 

 

 

Note: Faulted zones are force armed when the area arms.

Press

 

To do this

You will hear

#

then

1

Arm all areas

3 short beeps

#

then

2

Arm area 1

1 short beep

#

then

3

Arm areas 1 & 2

2 short beeps

Note: Zones in a bad condition are force armed when the area arms.

#

then

0

Disarm all areas

1 long beep

#, 5, 4, 0, n*

Toggles the output

1 short beep = on

(* Use outputs 1, 2, 3, or 4 in place of n) 1 long beep = off

 

(Enter output descriptions below)

4 short beeps = restricted

1._________________________ 3. _________________________

2._________________________ 4. _________________________

PhoneAccess™ Quick Commands

Press

 

To do this

You will hear

#

then

1

Arm all areas

3 short beeps

#

then

2

Arm area 1

1 short beep

#

then

3

Arm areas 1 & 2

2 short beeps

Note: Zones in a bad condition are force armed when the area arms.

#

then

0

Disarm all areas

1 long beep

#, 5, 4, 0, n*

Toggles the output

1 short beep = on

(* Use outputs 1, 2, 3, or 4 in place of n) 1 long beep = off

 

(Enter output descriptions below)

4 short beeps = restricted

1._________________________ 3. _________________________

2._________________________ 4. _________________________

Cut along dotted lines

XR20 Appendix

35

Image 39 Master Lock XR20 manual PhoneAccess Users Guide, Press To do this You will hear
Contents XR20 Area Systems All/Perimeter and Home/Away SystemsSecurity Command Users Guide Practice your escape plans Decide where to meetDraw a floorplan of your home or business Develop escape routesTest Your System Weekly Security Command keypadAbout Your Security System Parts of the SystemSecurity Command Keypad Character Keypad User Options MenuSelect keys Special Security Command Messages Special Security Command TonesSystem Trouble or Service Required Understanding Security System Terms Armed Status Exit ErrorCentral Station Monitoring StatusArming Functions How your System OperatesArea System Arming Arming the SystemExample Office no YES Disarming an Area System Area System DisarmingArming an All/Perimeter System All/Perimeter System ArmingSystem Ready/System Not Ready Keypad Displays Instant ArmingDisarming During an Alarm All/Perimeter System DisarmingDisarming an All/Perimeter System Arming a Home/Away System Home/Away System ArmingEasy Exit Feature Home/Away System DisarmingDisarming a Home/Away System Menu Option Description Security Command User MenuTo access the User Menu User Menu OptionsSelecting Zone Activity Check User Check-inZone Activity Check Sending a Check-in ReportOutputs On Off Sensor ResetResetting the Sensors Enter your user code to reset sensorsUsing the Bypass Zones Function Bypass ZonesZone Monitor Using the Zone Monitor Function Using the System Test FunctionSystem Test User Codes User Code Authority LevelsAdding User codes Changing User codes 6a. Temp Code no YES6c. ARM only no YES Deleting User codes Setting an Arming and Disarming ScheduleAmbush Codes SchedulesExtending a Closing Schedule Setting the Date and TimeExtended Schedules Date and TimeUsing the Display Events Function Display EventsZone Activity Check Event Display BYP Bypass RST Restore Zone Bypass Event DisplaysZone Event Displays User Check-in Event Displays Arming and Disarming Event DisplaysStation at the date and time shown User Code Change Event DisplaysSupervisory Event Displays Test report was sent on OctSystem Monitor Event Types There are 2 event types Service Request?System Monitor Event Displays An AC failure occurred at 105 AMSystem Setup Protection AreasOutputs HOW to Fill in this HOW to Fill in this Easy Entry Users Guide AppendixArming and Disarming AN ALL/PERIMETER System Disarming a Home/Away or All/Perimeter System Using the Alert ButtonsFA113 Users Guide Arming a Home/Away or All/Perimeter SystemArea Name Pager Direct Users GuideArea Names Pager DirectAlphanumeric Pager Display Numeric Pager DisplayPhoneAccess Users Guide You will hearPress To do this You will hear Voice Module Common Keypad Displays Message Meaning Possible SolutionsIndex This page has been intentionally left blank LT-0303 5/02