GARAGE TOUCHPAD INDICATORS

The green READY light shows the status of the zones in your system:

ON indicates that all zones are secure and the system is ready to be armed.

FLASHING indicates that at least one zone is open. To determine the open zone, count the number of flashes and refer to the zone list on your security panel.

OFF indicates that the optional second deadbolt is not locked. If there are two deadbolts in the system, the other deadbolt must be locked before the system can be armed.

The red ARMED light ON indicates that the system is armed.

BLINKING with the siren sounding indicates that the system is in alarm.

BLINKING with no siren indicates Alarm Memory (the alarm has been silenced or timed out). To determine the zone in alarm, count the number of flashes and refer to the zone list on your security panel. Press SILENCE to clear the alarm memory. (see page 13)

The yellow STAY light ON indicates that the system is armed in the STAY mode, allowing free movement throughout the premises, while maintaining perimeter protection.

The red FIRE light will flash to indicate that the system is in a Fire Alarm Condition*. If a fire is in progress, evacuate the premises immediately!

*Note: This feature may not apply to your system. Consult your installer to determine if your system includes fire protection.

The yellow trouble TBL light will light and the Touchpad sounder will pulse to indicate that a system trouble is present. If zone(s) have been bypassed, TBL will light steadily. (See SYSTEM TROUBLE ERROR CODES, Page 17).

The green AC Light ON indicates that AC Power is present.

READY ARMED STAY FIRE TBL

4

Image 4
Contents Napco Introduction Important Test Your System WeeklyTable of Contents Garage Touchpad Indicators Ready Armed Stay Fire TBLGarage Touchpad Controls Emergency ButtonsArming When Leaving Press the Away button on the TouchpadBypassing Faulted Zones System will arm with the faulted zones bypassedPress the Bypass button Press either the Stay or Away buttonArming When Staying Home Press the Stay button on the TouchpadCheck the Garage Touchpad indicators Arming and Leaving with Others StayingExiting with the System Already Armed Exit the garageIndicate the system has armed Emergency Buttons Disarming When Returning Home Disarming the SystemIf an alarm occurs while you are at home Silencing AN AlarmIf an alarm occurs while you are away Fire Protection FireWould You Like More Safety Information? Preparing a Fire Escape PlanFamily Rehearsal Important! Read CarefullySystem Trouble Error Codes ReadyNone Zone List Adding additional IFOBs to your system Enrolling a NEW F IfobRemoving IFOBs from the system Lost GAR AGE Door Opener Mode Lost Opener ModeFederal Communications Commission FCC Part 68 Statement Page Page Napco Limited Warranty Page Following Statement is Required by the FCC Publicly traded on Nasdaq Symbol Nssc