Napco Security Technologies GEM-K2AS manual Advanced Features, ZONE02, Bypass, Wait

Page 23

ADVANCED FEATURES

 

FAULT/

A C O N

ZONE02

 

 

 

 

 

BYPASS

A C O N

 

 

 

Security Bypass/Unbypass

(Security Bypass programmed? !YES !NO). In high-security applications, zones may be bypassed (or unbypassed) only if a valid code is entered first, as follows:

1.Enter a User Code valid for bypass, then press B. "BYPASS" will display.

2.Press Bthen the zone number (or vice versa) to deactivate that zone. Similarly, a bypassed zone may be unbypassed using the same procedure. (This feature avail- able for the GEM-P9600/3200 panels only).

 

WAIT

Start Exit Time After Ringback

 

(For Commercial Burglary Systems only) (Optional - Start Exit Time

A C O N

 

 

programmed? !YES !NO).

 

 

 

 

If your system reports to a central station, your panel may have been programmed to start

 

 

 

 

exit delay after the central-station ringback (verification) signal. Then, after arming, your

system will communicate to the central station. After the central station acknowledges receipt (ringback), exit delay will start. If ringback is not heard within about 30 seconds, a communication problem may exist; call for service. The Start Exit Time function may then be used to manually start the exit delay, however reporting capability may be sacrificed. (If your system does not report or the ringback feature was not programmed, exit delay will start as soon as your code is entered. Also note that if an exception window is programmed, and the closing is within that window, no ringback is provided. Ask your alarm professional if this feature is enabled).

Exit-Delay Restart

(Exit-Delay Restart programmed? !YES !NO).

On arming, the programmed exit delay will start. After the exit door has been opened and then closed, exit delay will change to 60 seconds. Thus, a long exit delay may be programmed, which will immediately be reduced to 60 seconds upon exiting. If re-entry occurs during that 60 seconds, exit delay will restart once again (and only once again) at 60 seconds. If so programmed, re-entry within 60 seconds after exit delay has expired will cause the alarm to sound a 2-second warning (in addition to the entry sounder) to remind the user to disarm.

23

Image 23
Contents AC on Ready Operating Guide for yourTest your sounding device Test your telephone line IntroductionImportant Test Your System Weekly Table of Contents AC on Keypad Controls & IndicatorsStay ResetEnter Arming AW AY Setting the Alarm When Leaving Armrst CantARM ArmznfCANT/ARM SystblEXX-XX READY1System Arming in Stay ModeArming Stay Protecting Yourself AT Home Armed Instant Protection Xxxsec Turning OFF the AL ARM Disarming When ReturningDisarm Hour Zone 24-Hour Zones programmed? !YES !NO Day Zone Day Zones programmed? !YES !NOTrbl Fire ProtectionFire ZonexxImportant! Read Carefully Preparing a Fire Escape PlanFamily Rehearsal Floorplan FloorplanLimitations of Fire Alarm Warning System Function Menu For user? !YES !NO R nO n / C h i me Y e s / N o L a y / Ar m 1 4/ / N o On Zone 1 has not been received Central Station Monitoring Communicator FeaturesWait Advanced FeaturesZONE02 BypassPage Programming User Codes Programming OptionalIntroduction User Programming Example Select the Program Mode as followsARMED1 Keypad MessagesExitxx Armsnd AlarmCancel ArmsilCode WrongArea TimeOvrr AcfailLobatt CommflClosing Window Optional. a GlossaryGlossary Priority Zone a zone that System Trouble Error Codes Following Statement is Required by the FCC Napco Limited Warranty