CLEARANCES AND HEIGHT REQUIREMENTS
10"
8"
6"
21/2"
Heat
Resistant
Material
8" 14" 201/2" 245/8" 28"
| 
 | Example: A mantel may project from the wall a maximum of 21/2" at a mini- | |
| 
 | Heater in | mum of 14" above the opening, and a maximum of 6" at a minimum | 
| 
 | of 201/2" above the opening. | |
| 
 | Fireplace or | |
| 
 | 
 | |
| 
 | Firebox | 
 | 
| 
 | Figure 7 - Minimum Mantel Clearance with No Hood  | |
| 
 | 12" | 
 | 
| 
 | 10" | 
 | 
| 
 | 8" | 
 | 
| 
 | 6" | 
 | 
| Heat | 21/2" | 
 | 
| Resistant | 
 | 
 | 
| Material | 
 | 
 | 
| 
 | 8" 141/2" 185/8" 221/2" | 26" | 
| 
 | Hood | 
 | 
| 
 | Example: | A mantel may project from the wall a maximum of 21/2" at a | 
| 
 | Heater in | minimum of 8" above the opening, and a maximum of 6" at a mini- | 
| 
 | Fireplace or | mum of 141/2" above the opening. | 
| 
 | Firebox | 
 | 
| 
 | Figure 8 - Minimum Mantel Clearance with Hood - All Models | |
| 14 | 70D0004 |