Monessen Hearth TPB18, TPB30, TPB24 manual Special Requirements

Page 41

SPECIAL REQUIREMENTS CONTINUED

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b)EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:

1.The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

2.The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

(e)A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

70D0004

41

Image 41
Contents What to do if YOU Smell GAS Read and Save These InstructionsContents Owner Important Safety InformationInstaller Massachussetts Residents only Make Sure YOU have Received ALL Parts What YOU will Need for InstallationGetting Started Product Features and Specifications Adequate Combustion and Ventilation AIR General Installation InformationCodes BTU / Hr = Hearth Minimum Dimension Fireplace and Hearth DimensionsHeight of Restriction Minimum Depth of Fireplace/Firebox Placement in a Fireplace with a Restrictive BarrierSidewall and Ceiling Clearances Clearances and Height RequirementsClearances and Height Requirements Measuring Heat Resistant Material for Mantel Minimum Mantel Clearance with No Hood -TPB18 Mum of 10 at a minimum of 28 above the opening Minimum Clearance above Combustible Flooring Floor ClearanceBefore Fully Installing the Unit Installing Vented ApplicationsBefore Installing the Appliance Damper Stop InstallationPlacing and Securing Appliance Installing Vented ApplicationsAssembly Procedure Flexible Tube Manual Shutoff Gas Supply Inlet Valve Connecting the GASMILLI-VOLT Valve Control Figure Checking GAS PressureATE Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Complete MILLI-VOLT System Check Connecting Remote ReceiverChecking System Operation Installing Charred Timber Logs on Burner LOG PlacementInstalling Left Base Log #3 Installing Left Top Log #5 Placing Rock Wool Installing Right Top Log #6Steel BAR Grate Installation Riser and Steel BAR Grate InstallationOptional Riser Installation Andiron Installation Optional Cast Iron Grate and Andiron InstallationCast Iron Grate Installation Placing the Decorative Rock Flame AppearanceChecking the Pilot Flame MILLI-VOLT Control and Thermostat ControlOperating Instructions Checking the Burner FlameWhat to do if YOU Smell GAS Operating InstructionsTo Turn OFF GAS to Heater Cleaning and Servicing Operating Instructions and Cleaning and ServicingObserved Problem Possible Cause Remedy TroubleshootingODS/pilot lights, but flame Burner Assembly Replacement PartsAccessories Sold Separately Replacement Parts ListCTCL18 CTCL24 CTCL30 Charred Timber Logs70D0004 Carbon Monoxide Detector Requirements Special Requirements Basic Warranty Lifetime WarrantyFive Year Warranty