Monessen Hearth CSVF20SPV, CSVF30SPV manual Checking GAS Pressure and Connecting Remote Receiver

Page 15

CHECKING GAS PRESSURE AND CONNECTING REMOTE RECEIVER

The heater gas inlet connection is 3/8" NPT at the valve. The

WARNING

 

 

inlet is located on left side of stove. Remove front control plate

Connecting directly to an unregulated

 

to better access the inlet.

 

 

propane/L.P.G. tank can cause an

When tightening up the joint to the valve, hold the valve securely

 

 

explosion.

with a wrench to prevent movement.

 

 

Test all gas joints from the gas meter to the heater valve for

 

 

 

 

leaks using a gas analyzer or soap and water solution after completing connection. DO NOT USE AN OPEN FLAME. Check the gas pressure with the appliance burning and the control set to HIGH.

MILLIVOLT CONTROL (FIGURE 10)

Test Port “OUT”

The valve regulator controls the burner pressure which should be checked at the pressure test point.

If outlet pressure is low, check inlet pressure against data plates or manual.

Turn captured slotted screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “OUT” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks.

Figure 10 - Pressure Test Point Location

Milli-Volt Control

NOTE: Remove control panel to access gas valve and ignitor battery module.

CONNECTING REMOTE RECEIVER

1.Remove cover on control panel to show opening for remote receiver. See Figure 11.

2.Cut cable to length (approximately 12") for placement in the fireplace.

3.Strip back 1/4" of the insulation from free end of each wire. Do not cut off wire connector.

4.Connect two .25 female connectors to the wires at free end of the cable.

5.Insert the wire connector into the receiver. If remote does not have plug-in connector, strip back 1/4" of insulation. Insert wire into terminal and tighten screws.

6.Connect the connectors to the two .25" male connectors located on the left side when facing the unit. See Figure 11. Do not let the wire touch the grate or burners.

7.Slide remote receiver in the opening of control panel. Use two screws provided to attach remote receiver to the control panel. See Figure 11.

8.Replace Cover. See Figure 11.

NOTE: Do not place remote in combustion chamber.

Remote Receiver

Cover

Figure 11 - Installing Remote Receiver

58D56002

15

Image 15
Contents Models CSVF20SNV CSVF30SNV CSVF20SPV CSVF30SPV What to do if YOU Smell GASRead and Save These Instructions Contents Important Safety Information InstallerOwner From Optional Door Knob Product FeaturesOn/Off Switch Handle Optional Remote Receiver Piezo Hi/Lo Knob28 1 DimensionsCSVF20S CSVF30S 26 3What YOU will Need for Installation Getting StartedMake Sure YOU have Received ALL Parts Product Specifications General Installation Information CodesAdequate Combustion and Ventilation AIR L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 Ft Counter Cast Iron StoveClearances / Height Requirements Ceiling Side Wall MantelCeiling Placing Stove in Alcove Clearances / Height RequirmentsAsh Lip Control Door Removing Unit from CratePlastic Bag Pallet Hearth DoorFlexible Tube Manual Shutoff Gas Supply Inlet Valve Connecting the GASRemote Receiver Cover Checking GAS Pressure and Connecting Remote ReceiverConnecting Remote Receiver Millivolt Control FigureComplete Millivolt System Check Electrical Wiring MILLI-VOLTConnecting Optional Wall Switch or Thermostat Checking System OperationAsh Face Plate Installing Thermostat Sensor Option Sold SeparatelyKnob Thermo Bulb Stat Sensor Wiring Harnesses Screws DoorOptional Fan Operating Thermostat SensorThermo Bulb Plastic Clip Piezo Ignitor Hi/Lo Knob PilotTop Left Log #4 Bottom Log #2 Support Bracket LOG PlacementFor Natural Thermocouple For LP Rock Wool InstallationBend in Rock Wool Tray Rock Wood ThermocoupleMiddle Log Flame AppearanceChecking Burner Flame Operating InstructionsOff/Pilot/On Knob Optional Thermostat Sensor Operating InstructionsMILLI-VOLT and Thermostat Control Lighting Instructions Cleaning and Servicing Operating Instructions and Cleaning and ServicingLogs Replacement Parts ListBurner Assembly Replacement Parts58D0061 58D0056 CSVF20 CSVF3033D0070 33D0071 58D0193 58D0435Observed Problem Possible Cause Remedy TroubleshootingODS/pilot lights, but flame 58D6002 58D56002 Limited Lifetime Warranty