Monessen Hearth manual Models CSVF20SNV CSVF30SNV CSVF20SPV CSVF30SPV

Page 1

UNVENTED GAS

CAST IRON STOVE

INSTALLATION AND OPERATING

INSTRUCTIONS

MODELS:

CSVF20SNV CSVF30SNV

CSVF20SPV CSVF30SPV

Natural Gas or

Propane/LPG

Milli-Volt Control

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to page 8.

WARNINGS

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

READ AND SAVE THESE INSTRUCTIONS

Image 1
Contents What to do if YOU Smell GAS Models CSVF20SNV CSVF30SNV CSVF20SPV CSVF30SPVRead and Save These Instructions Contents Installer Important Safety InformationOwner From On/Off Switch Product FeaturesHandle Optional Remote Receiver Piezo Hi/Lo Knob Optional Door KnobCSVF20S CSVF30S Dimensions26 3 28 1Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Product Specifications Codes General Installation InformationAdequate Combustion and Ventilation AIR L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 Ft Counter Cast Iron StoveCeiling Side Wall Mantel Clearances / Height RequirementsCeiling Placing Stove in Alcove Clearances / Height RequirmentsPlastic Bag Removing Unit from CratePallet Hearth Door Ash Lip Control DoorFlexible Tube Manual Shutoff Gas Supply Inlet Valve Connecting the GASConnecting Remote Receiver Checking GAS Pressure and Connecting Remote ReceiverMillivolt Control Figure Remote Receiver CoverConnecting Optional Wall Switch or Thermostat Electrical Wiring MILLI-VOLTChecking System Operation Complete Millivolt System CheckKnob Thermo Bulb Stat Sensor Wiring Harnesses Installing Thermostat Sensor Option Sold SeparatelyScrews Door Ash Face PlateThermo Bulb Plastic Clip Operating Thermostat SensorPiezo Ignitor Hi/Lo Knob Pilot Optional FanTop Left Log #4 Bottom Log #2 Support Bracket LOG PlacementBend in Rock Wool Tray Rock Wood Rock Wool InstallationThermocouple For Natural Thermocouple For LPChecking Burner Flame Flame AppearanceOperating Instructions Middle LogOff/Pilot/On Knob Optional Thermostat Sensor Operating InstructionsMILLI-VOLT and Thermostat Control Lighting Instructions Cleaning and Servicing Operating Instructions and Cleaning and ServicingLogs Replacement Parts ListBurner Assembly Replacement Parts33D0070 33D0071 58D0193 CSVF20 CSVF3058D0435 58D0061 58D0056Observed Problem Possible Cause Remedy TroubleshootingODS/pilot lights, but flame 58D6002 58D56002 Limited Lifetime Warranty