IMPORTANT SAFETY INFORMATION

Continued from page 3

15.This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be pro- vided. See page 8.

16.Keep room area clear and free from combustible materi- als, gasoline and other flammable vapors and liquids.

17.Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appli- ance.

18.Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, addition mechanical ventilation is recommended.

19.During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.

20.Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. Refer to the National Fuel Gas Code.

21.The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

22.The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

23.Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

24.Never burn solid fuels in an unvented room heater, fire- place or stove.

25.Do not set kettles or humidifying devices on top of stove.

26.The stove door/screen must be closed when the appli- ance is operating. The screen shall have openings for induction of combustion air.

4

58D6002

Image 4
Contents What to do if YOU Smell GAS Models CSVF20SNV CSVF30SNV CSVF20SPV CSVF30SPVRead and Save These Instructions Contents Installer Important Safety InformationOwner From Product Features On/Off SwitchHandle Optional Remote Receiver Piezo Hi/Lo Knob Optional Door KnobDimensions CSVF20S CSVF30S26 3 28 1Getting Started What YOU will Need for InstallationMake Sure YOU have Received ALL Parts Product Specifications Codes General Installation InformationAdequate Combustion and Ventilation AIR Counter Cast Iron Stove L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 FtCeiling Side Wall Mantel Clearances / Height RequirementsCeiling Clearances / Height Requirments Placing Stove in AlcoveRemoving Unit from Crate Plastic BagPallet Hearth Door Ash Lip Control DoorConnecting the GAS Flexible Tube Manual Shutoff Gas Supply Inlet ValveChecking GAS Pressure and Connecting Remote Receiver Connecting Remote ReceiverMillivolt Control Figure Remote Receiver CoverElectrical Wiring MILLI-VOLT Connecting Optional Wall Switch or ThermostatChecking System Operation Complete Millivolt System CheckInstalling Thermostat Sensor Option Sold Separately Knob Thermo Bulb Stat Sensor Wiring HarnessesScrews Door Ash Face PlateOperating Thermostat Sensor Thermo Bulb Plastic ClipPiezo Ignitor Hi/Lo Knob Pilot Optional FanLOG Placement Top Left Log #4 Bottom Log #2 Support BracketRock Wool Installation Bend in Rock Wool Tray Rock WoodThermocouple For Natural Thermocouple For LPFlame Appearance Checking Burner FlameOperating Instructions Middle LogOperating Instructions Off/Pilot/On Knob Optional Thermostat SensorMILLI-VOLT and Thermostat Control Lighting Instructions Operating Instructions and Cleaning and Servicing Cleaning and ServicingReplacement Parts List LogsReplacement Parts Burner AssemblyCSVF20 CSVF30 33D0070 33D0071 58D019358D0435 58D0061 58D0056Troubleshooting Observed Problem Possible Cause RemedyODS/pilot lights, but flame 58D6002 58D56002 Limited Lifetime Warranty