Monessen Hearth LX32DV Optional top vent application, After conversion to top vent configuration

Page 11

venting installation

LX Series Direct Vent Gas Fireplace

 

 

 

WARNING

After conversion to top vent configuration

 

 

 

 

the 4" (102 mm) flue pipe should be

 

 

concentric within the 6B\," (175 mm) outer

 

 

collar (within 1/4").

 

 

 

Optional top vent application

The appliance is shipped as a rear vent unit. If the installa- tion layout requires the unit to be a top vent configuration the appliance can be converted by the following steps.

When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.

1.Remove the eight (8) screws securing the flue pipe adapter to the fireplace body. Figure 7

2.Set the flue pipe adapter aside, complete with the gasket. Do not damage the gaskets as the adapter and gasket must be refitted.

3.Remove the eight (8) screws securing the flue pipe cover to the top of the intake box and remove the cover and gasket. Figure 7

Screws

Flue Pipe

Cover

Flue Cover

Screws

Flue Pipe

FP1992

Figure 8 -

Remove Flue Pipe

Flue Pipe

Screws

FP1991

Flue Pipe

Adapter

Figure 7 -

Remove 16 Screws from Flue Pipe

Adapter and Flue Pipe Cover

4.Remove eight (8) screws securing the flue pipe to the back of the intake box and remove the pipe and gasket. Figure 8

5.Replace flue pipe to top of firebox. Ensure the gasket is in place and undamaged. Secure with eight (8) screws. Figure 9

6.Place the flue pipe cover and gasket removed in step 3 over the flue opening in bottom of the intake box.

Figure 9 -

FP1993

Attach Flue Pipe to Top

Vent Configurations

7.Refit the flue pipe adapter and gasket to the top of fire- place. Secure the adapter with eight (8) screws removed in Step 1.

51D0528

11

Image 11
Contents What to do if YOU Smell GAS Lexington Direct Vent Gas FireplaceCongratulations ContentsPlease leave these instructions with the appliance Important Safety InformationInstaller OwnerPlease Read the Following Carefully Important Safety InformationCode Approval GAS pressures Product SpecificationsGas Specifications & Orifice Size High ElevationsLX32 Fireplace & Framing Dimensions Fireplace and Framing DimensionsFireplace Framing Installation InformationBefore You Start Fireplace Location Installation InformationFor the exact width of the face ClearancesClearances to combustibles Mantel clearances Hearth requirementsFinishing Material Secure Fireplace to floor or framingConcentric within the 6B\, 175 mm outer After conversion to top vent configurationOptional top vent application 4 102 mm flue pipe should beFailure to follow these instructions will void the warranty Installation precautionsVenting Installation Combustible Clearances for Vent Pipe Venting InstallationFor vertical termination Installation planningInstalling a vent system in an outside chase For horizontal terminationGeneral Venting Information Termination Location Venting InstallationSystem How To Use The Vent GraphFollowing vent installation instructions to determine Vent Graph should be read in conjunction withWall. This will cause a fire hazard Rear Wall Vent installationDo not recess vent termination into any Horizontal through the wall ter- mination configurations Elbow Total Angular Variation 270 Example According to the vent graph Page 16Maximum horizontal vent length in a system with a Vertical through-the-roof applica- tions Below Grade InstallationsFlat Ceiling Installation Installation for Vertical TERMINA- TionFully twist-locked. Page 17, Figure Assemble the desired lengths of pipe and elbows necEssary to reach from the burner system flue up through Firestop. Be sure pipe and elbow connections areCheck gas type Installing gas piping to fireplace locationPropane/LP Natural GasElectrical Wiring Heater 110V circuit Remote Wall mounted SwitchDo not connect wall switch to Each clamp has a quick spring force. When Final InstallationReinstalling clamps, keep fingers clear Glass Frame RemovalPersonal injury LOG PlacementInstalL logs and rock wool ember material in firebox Logs supplied with the unitRear Log #1 Place top left log #4 on two pins on left mid log. Figure Center Log #8 Air Space Under Rear Log 20 to 50% 30 to AIR Restrictor Adjustment100% Factory Setting Install Facing Facing InstallationOperating Instructions Leak testing Never use an open flame to check for gas leaksInitial lighting Operating Instructions Approved leak testing methodPilot position Main burner switchLighting the burner Venting system Cleaning and maintenanceCleaning glass Firebox CleaningBlower Wiring Diagram for BlowerObserved Problem Possible Cause Remedy TroubleshootingReplacement Parts Replacement Parts Nantucket Decorative Arch Optional AccessoriesOptional Accessories LX Series Direct Vent Gas Fireplace LX Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Mhsc

LX36DV, LX32DV specifications

The Monessen Hearth LX36DV and LX32DV are premium direct vent gas fireplaces designed to provide warmth and ambiance in any living space. Both models showcase innovative engineering and elegant designs, making them a popular choice for homeowners seeking efficient heating solutions.

One of the main features of the LX36DV and LX32DV is their versatile design. Both units are available in various configurations, allowing them to seamlessly integrate into a range of architectural styles, from contemporary to traditional. Their clean face design and beveled edges contribute to a sleek, attractive appearance that enhances any room's aesthetic.

Efficiency is another standout characteristic of these fireplaces. Equipped with advanced gas burner technology, the LX36DV and LX32DV deliver an impressive heat output while maintaining a high efficiency rating. The direct vent system ensures that combustion gases are safely expelled outside, making it a safe alternative to traditional wood-burning fireplaces. This feature not only improves indoor air quality but also contributes to overall energy conservation.

The LX36DV and LX32DV also offer customizable options to enhance user experience. Customers can choose from various front styles, finishes, and media options, allowing for personalization that matches individual tastes. The addition of decorative glass or colorful crushed fireglass can transform the look of the fireplace, creating a unique focal point in the room.

In terms of technology, both models are equipped with remote control capabilities, allowing users to adjust flame height and heat settings from anywhere in the room. This convenience ensures optimal comfort while eliminating the need for manual adjustments. Additionally, these fireplaces come with innovative electronic ignition systems that provide reliable startup every time.

Safety features are prioritized in the design of the LX36DV and LX32DV. Each unit comes with safety screen options and can be modified to include childproof doors, making them a practical choice for families. The advanced flame sensing technology provides peace of mind as it automatically adjusts in response to room conditions.

In conclusion, the Monessen Hearth LX36DV and LX32DV are exemplary gas fireplaces that combine style, efficiency, and safety. With their customizable design, advanced technologies, and user-friendly features, these models stand out in the market, offering unrivaled warmth and elegance to any home. Whether you are heating a cozy family room or making a statement in a grand living area, these fireplaces provide both functionality and charm.