Monessen Hearth LX36DV, LX32DV operating instructions Initial lighting, Operating Instructions

Page 34

LX Series Direct Vent Gas Fireplace

OPERATING INSTRUCTIONS

 

 

for your safety read before lighting

WARNING

If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance is equipped with a pilot which must be lit with built-in ignitor while following these instructions exactly.

B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the appliance.

Open windows.

Do not attempt to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instruc- tions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

Lighting pilot for the first time

initial lighting

Purge air from the supply line as follows:

Open main shutoff valve.

Unscrew main pressure test point.

Leave inlet test screw open until gas comes in.

When gas is flowing, tighten inlet screw immediately.

leak testing

WARNING

Never use an open flame to check for gas leaks.

1.Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture.

2.Next check for gas leaks at the burner with soap and water mixture.

3.Check the pilot for gas leaks with soap and water mixture.

34

51D0528

Image 34
Contents Lexington Direct Vent Gas Fireplace What to do if YOU Smell GASContents CongratulationsOwner Important Safety InformationInstaller Please leave these instructions with the applianceCode Approval Important Safety InformationPlease Read the Following Carefully High Elevations Product SpecificationsGas Specifications & Orifice Size GAS pressuresFireplace and Framing Dimensions LX32 Fireplace & Framing DimensionsBefore You Start Installation InformationFireplace Framing Installation Information Fireplace LocationMantel clearances Hearth requirements ClearancesClearances to combustibles For the exact width of the faceSecure Fireplace to floor or framing Finishing Material4 102 mm flue pipe should be After conversion to top vent configurationOptional top vent application Concentric within the 6B\, 175 mm outerVenting Installation Installation precautionsFailure to follow these instructions will void the warranty Venting Installation Combustible Clearances for Vent PipeFor horizontal termination Installation planningInstalling a vent system in an outside chase For vertical terminationVenting Installation General Venting Information Termination LocationVent Graph should be read in conjunction with How To Use The Vent GraphFollowing vent installation instructions to determine SystemDo not recess vent termination into any Rear Wall Vent installationWall. This will cause a fire hazard Horizontal through the wall ter- mination configurations Maximum horizontal vent length in a system with a Example According to the vent graph Page 16Elbow Total Angular Variation 270 Below Grade Installations Vertical through-the-roof applica- tionsInstallation for Vertical TERMINA- Tion Flat Ceiling InstallationFirestop. Be sure pipe and elbow connections are Assemble the desired lengths of pipe and elbows necEssary to reach from the burner system flue up through Fully twist-locked. Page 17, FigureInstalling gas piping to fireplace location Check gas typeNatural Gas Propane/LPElectrical Wiring Do not connect wall switch to Remote Wall mounted SwitchHeater 110V circuit Glass Frame Removal Final InstallationReinstalling clamps, keep fingers clear Each clamp has a quick spring force. WhenLogs supplied with the unit LOG PlacementInstalL logs and rock wool ember material in firebox Personal injuryRear Log #1 Place top left log #4 on two pins on left mid log. Figure Center Log #8 Air Space Under Rear Log 100% Factory Setting AIR Restrictor Adjustment20 to 50% 30 to Facing Installation Install FacingInitial lighting Leak testing Never use an open flame to check for gas leaksOperating Instructions Approved leak testing method Operating InstructionsLighting the burner Main burner switchPilot position Firebox Cleaning Cleaning and maintenanceCleaning glass Venting systemWiring Diagram for Blower BlowerTroubleshooting Observed Problem Possible Cause RemedyReplacement Parts Replacement Parts Optional Accessories Nantucket Decorative ArchOptional Accessories LX Series Direct Vent Gas Fireplace LX Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings

LX36DV, LX32DV specifications

The Monessen Hearth LX36DV and LX32DV are premium direct vent gas fireplaces designed to provide warmth and ambiance in any living space. Both models showcase innovative engineering and elegant designs, making them a popular choice for homeowners seeking efficient heating solutions.

One of the main features of the LX36DV and LX32DV is their versatile design. Both units are available in various configurations, allowing them to seamlessly integrate into a range of architectural styles, from contemporary to traditional. Their clean face design and beveled edges contribute to a sleek, attractive appearance that enhances any room's aesthetic.

Efficiency is another standout characteristic of these fireplaces. Equipped with advanced gas burner technology, the LX36DV and LX32DV deliver an impressive heat output while maintaining a high efficiency rating. The direct vent system ensures that combustion gases are safely expelled outside, making it a safe alternative to traditional wood-burning fireplaces. This feature not only improves indoor air quality but also contributes to overall energy conservation.

The LX36DV and LX32DV also offer customizable options to enhance user experience. Customers can choose from various front styles, finishes, and media options, allowing for personalization that matches individual tastes. The addition of decorative glass or colorful crushed fireglass can transform the look of the fireplace, creating a unique focal point in the room.

In terms of technology, both models are equipped with remote control capabilities, allowing users to adjust flame height and heat settings from anywhere in the room. This convenience ensures optimal comfort while eliminating the need for manual adjustments. Additionally, these fireplaces come with innovative electronic ignition systems that provide reliable startup every time.

Safety features are prioritized in the design of the LX36DV and LX32DV. Each unit comes with safety screen options and can be modified to include childproof doors, making them a practical choice for families. The advanced flame sensing technology provides peace of mind as it automatically adjusts in response to room conditions.

In conclusion, the Monessen Hearth LX36DV and LX32DV are exemplary gas fireplaces that combine style, efficiency, and safety. With their customizable design, advanced technologies, and user-friendly features, these models stand out in the market, offering unrivaled warmth and elegance to any home. Whether you are heating a cozy family room or making a statement in a grand living area, these fireplaces provide both functionality and charm.