Monessen Hearth LX32DV, LX36DV Important Safety Information, Installer, Owner

Page 3

IMPORTANT SAFETY INFORMATION

LX Series Direct Vent Gas Fireplace

 

 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference.

WARNING

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.

Any change to this fireplace or its controls can be dangerous.

Improper installation or use of this fireplace can cause serious injury or death from fire, burns, explosions, electrical shock and carbon monoxide poisoning.

This fireplace is a vented product. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, combustion leakage can occur.

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, the fire- place may not have been installed properly. Get fresh air at once! Have the fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply.

do not try to light any appliance.

do not touch any electrical switch; do not use any phone in your building .

immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42" from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high temperatures. Keep chil- dren and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touch- ing.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace.

8.Turn fireplace off and let cool before servicing, install- ing, or repairing. Only a qualified service person should install, service, or repair the fireplace. Have burner system inspected annually by a qualified service person.

9.You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, pet hair, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a quali- fied service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, Page 37.

11.Keep the area around your fireplace clear of combus- tible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or deco- rations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Never place anything on top of fireplace.

51D0528

Image 3
Contents What to do if YOU Smell GAS Lexington Direct Vent Gas FireplaceCongratulations ContentsPlease leave these instructions with the appliance Important Safety InformationInstaller OwnerImportant Safety Information Code ApprovalPlease Read the Following Carefully GAS pressures Product SpecificationsGas Specifications & Orifice Size High ElevationsLX32 Fireplace & Framing Dimensions Fireplace and Framing DimensionsInstallation Information Before You StartFireplace Framing Fireplace Location Installation InformationFor the exact width of the face ClearancesClearances to combustibles Mantel clearances Hearth requirementsFinishing Material Secure Fireplace to floor or framingConcentric within the 6B\, 175 mm outer After conversion to top vent configurationOptional top vent application 4 102 mm flue pipe should beInstallation precautions Venting InstallationFailure to follow these instructions will void the warranty Combustible Clearances for Vent Pipe Venting InstallationFor vertical termination Installation planningInstalling a vent system in an outside chase For horizontal terminationGeneral Venting Information Termination Location Venting InstallationSystem How To Use The Vent GraphFollowing vent installation instructions to determine Vent Graph should be read in conjunction withRear Wall Vent installation Do not recess vent termination into anyWall. This will cause a fire hazard Horizontal through the wall ter- mination configurations Example According to the vent graph Page 16 Maximum horizontal vent length in a system with aElbow Total Angular Variation 270 Vertical through-the-roof applica- tions Below Grade InstallationsFlat Ceiling Installation Installation for Vertical TERMINA- TionFully twist-locked. Page 17, Figure Assemble the desired lengths of pipe and elbows necEssary to reach from the burner system flue up through Firestop. Be sure pipe and elbow connections areCheck gas type Installing gas piping to fireplace locationPropane/LP Natural GasElectrical Wiring Remote Wall mounted Switch Do not connect wall switch toHeater 110V circuit Each clamp has a quick spring force. When Final InstallationReinstalling clamps, keep fingers clear Glass Frame RemovalPersonal injury LOG PlacementInstalL logs and rock wool ember material in firebox Logs supplied with the unitRear Log #1 Place top left log #4 on two pins on left mid log. Figure Center Log #8 Air Space Under Rear Log AIR Restrictor Adjustment 100% Factory Setting20 to 50% 30 to Install Facing Facing InstallationLeak testing Never use an open flame to check for gas leaks Initial lightingOperating Instructions Operating Instructions Approved leak testing methodMain burner switch Lighting the burnerPilot position Venting system Cleaning and maintenanceCleaning glass Firebox CleaningBlower Wiring Diagram for BlowerObserved Problem Possible Cause Remedy TroubleshootingReplacement Parts Replacement Parts Nantucket Decorative Arch Optional AccessoriesOptional Accessories LX Series Direct Vent Gas Fireplace LX Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Mhsc

LX36DV, LX32DV specifications

The Monessen Hearth LX36DV and LX32DV are premium direct vent gas fireplaces designed to provide warmth and ambiance in any living space. Both models showcase innovative engineering and elegant designs, making them a popular choice for homeowners seeking efficient heating solutions.

One of the main features of the LX36DV and LX32DV is their versatile design. Both units are available in various configurations, allowing them to seamlessly integrate into a range of architectural styles, from contemporary to traditional. Their clean face design and beveled edges contribute to a sleek, attractive appearance that enhances any room's aesthetic.

Efficiency is another standout characteristic of these fireplaces. Equipped with advanced gas burner technology, the LX36DV and LX32DV deliver an impressive heat output while maintaining a high efficiency rating. The direct vent system ensures that combustion gases are safely expelled outside, making it a safe alternative to traditional wood-burning fireplaces. This feature not only improves indoor air quality but also contributes to overall energy conservation.

The LX36DV and LX32DV also offer customizable options to enhance user experience. Customers can choose from various front styles, finishes, and media options, allowing for personalization that matches individual tastes. The addition of decorative glass or colorful crushed fireglass can transform the look of the fireplace, creating a unique focal point in the room.

In terms of technology, both models are equipped with remote control capabilities, allowing users to adjust flame height and heat settings from anywhere in the room. This convenience ensures optimal comfort while eliminating the need for manual adjustments. Additionally, these fireplaces come with innovative electronic ignition systems that provide reliable startup every time.

Safety features are prioritized in the design of the LX36DV and LX32DV. Each unit comes with safety screen options and can be modified to include childproof doors, making them a practical choice for families. The advanced flame sensing technology provides peace of mind as it automatically adjusts in response to room conditions.

In conclusion, the Monessen Hearth LX36DV and LX32DV are exemplary gas fireplaces that combine style, efficiency, and safety. With their customizable design, advanced technologies, and user-friendly features, these models stand out in the market, offering unrivaled warmth and elegance to any home. Whether you are heating a cozy family room or making a statement in a grand living area, these fireplaces provide both functionality and charm.