VENTING INSTALLATION

LX Series Direct Vent Gas Fireplace

 

 

 

COMBUSTIBLE CLEARANCES FOR VENT PIPE

 

 

 

 

 

 

WARNING

This fireplace must be vented to the outside. The venting system must

 

 

 

 

NEVER be attached to a chimney serving a separate solid fuel burning

 

 

appliance. Each gas appliance must use a separate vent system. Do not

 

 

use common vent systems.

 

 

 

 

 

 

WARNING

Horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1" clearance all around the flue is acceptable at this point of penetration.

Vertical sections of this vent system require a minimum of 1" clearance to combustibles on all sides of the pipe.

*3"

**1"

Figure 10 -

Combustible Clearances for Vent Pipe

**1"

35(6

(911 mm)

FP2713

*A minimum of 3" clearance to the top is required along horizontal length until flue pipe penetrates outside wall.

**A minimum 1" clearance to combustibles permitted all around flue at outside wall

51D0528

13

Image 13
Contents What to do if YOU Smell GAS Lexington Direct Vent Gas FireplaceCongratulations ContentsInstaller Important Safety InformationOwner Please leave these instructions with the applianceCode Approval Important Safety InformationPlease Read the Following Carefully Gas Specifications & Orifice Size Product SpecificationsHigh Elevations GAS pressuresLX32 Fireplace & Framing Dimensions Fireplace and Framing DimensionsBefore You Start Installation InformationFireplace Framing Fireplace Location Installation InformationClearances to combustibles ClearancesMantel clearances Hearth requirements For the exact width of the faceFinishing Material Secure Fireplace to floor or framingOptional top vent application After conversion to top vent configuration4 102 mm flue pipe should be Concentric within the 6B\, 175 mm outerVenting Installation Installation precautionsFailure to follow these instructions will void the warranty Combustible Clearances for Vent Pipe Venting InstallationInstalling a vent system in an outside chase Installation planningFor horizontal termination For vertical terminationGeneral Venting Information Termination Location Venting InstallationFollowing vent installation instructions to determine How To Use The Vent GraphVent Graph should be read in conjunction with SystemDo not recess vent termination into any Rear Wall Vent installationWall. This will cause a fire hazard Horizontal through the wall ter- mination configurations Maximum horizontal vent length in a system with a Example According to the vent graph Page 16Elbow Total Angular Variation 270 Vertical through-the-roof applica- tions Below Grade InstallationsFlat Ceiling Installation Installation for Vertical TERMINA- TionEssary to reach from the burner system flue up through Assemble the desired lengths of pipe and elbows necFirestop. Be sure pipe and elbow connections are Fully twist-locked. Page 17, FigureCheck gas type Installing gas piping to fireplace locationPropane/LP Natural GasElectrical Wiring Do not connect wall switch to Remote Wall mounted SwitchHeater 110V circuit Reinstalling clamps, keep fingers clear Final InstallationGlass Frame Removal Each clamp has a quick spring force. WhenInstalL logs and rock wool ember material in firebox LOG PlacementLogs supplied with the unit Personal injuryRear Log #1 Place top left log #4 on two pins on left mid log. Figure Center Log #8 Air Space Under Rear Log 100% Factory Setting AIR Restrictor Adjustment20 to 50% 30 to Install Facing Facing InstallationInitial lighting Leak testing Never use an open flame to check for gas leaksOperating Instructions Operating Instructions Approved leak testing methodLighting the burner Main burner switchPilot position Cleaning glass Cleaning and maintenanceFirebox Cleaning Venting systemBlower Wiring Diagram for BlowerObserved Problem Possible Cause Remedy TroubleshootingReplacement Parts Replacement Parts Nantucket Decorative Arch Optional AccessoriesOptional Accessories LX Series Direct Vent Gas Fireplace LX Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Mhsc

LX36DV, LX32DV specifications

The Monessen Hearth LX36DV and LX32DV are premium direct vent gas fireplaces designed to provide warmth and ambiance in any living space. Both models showcase innovative engineering and elegant designs, making them a popular choice for homeowners seeking efficient heating solutions.

One of the main features of the LX36DV and LX32DV is their versatile design. Both units are available in various configurations, allowing them to seamlessly integrate into a range of architectural styles, from contemporary to traditional. Their clean face design and beveled edges contribute to a sleek, attractive appearance that enhances any room's aesthetic.

Efficiency is another standout characteristic of these fireplaces. Equipped with advanced gas burner technology, the LX36DV and LX32DV deliver an impressive heat output while maintaining a high efficiency rating. The direct vent system ensures that combustion gases are safely expelled outside, making it a safe alternative to traditional wood-burning fireplaces. This feature not only improves indoor air quality but also contributes to overall energy conservation.

The LX36DV and LX32DV also offer customizable options to enhance user experience. Customers can choose from various front styles, finishes, and media options, allowing for personalization that matches individual tastes. The addition of decorative glass or colorful crushed fireglass can transform the look of the fireplace, creating a unique focal point in the room.

In terms of technology, both models are equipped with remote control capabilities, allowing users to adjust flame height and heat settings from anywhere in the room. This convenience ensures optimal comfort while eliminating the need for manual adjustments. Additionally, these fireplaces come with innovative electronic ignition systems that provide reliable startup every time.

Safety features are prioritized in the design of the LX36DV and LX32DV. Each unit comes with safety screen options and can be modified to include childproof doors, making them a practical choice for families. The advanced flame sensing technology provides peace of mind as it automatically adjusts in response to room conditions.

In conclusion, the Monessen Hearth LX36DV and LX32DV are exemplary gas fireplaces that combine style, efficiency, and safety. With their customizable design, advanced technologies, and user-friendly features, these models stand out in the market, offering unrivaled warmth and elegance to any home. Whether you are heating a cozy family room or making a statement in a grand living area, these fireplaces provide both functionality and charm.