| 27 | |
|
|
|
|
| |
| SYMPTOM |
| PROBLEM | TEST SOLUTION | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Pilot lights |
| - Wiring / Connection | Inspect all wires, ensure good tight connections. Verify that all |
|
| Stops sparking |
|
| wiring is installed exactly as specified. |
|
| / pilot remains lit |
| - Wiring harness | Inspect the wiring harness, and verify the harness is tightly con- | |
| but burner will |
| |||
|
|
| nected to the module. Verify that you have 7 wires and they are | ||
| not turn on |
|
| ||
|
|
| connected in the right order. | ||
|
|
|
| ||
|
|
|
|
|
|
|
|
| - Module or Valve | Conduct the following test to verify if the problem is the module or | |
|
|
|
| valve. To measure voltages, turn multimeter to "DC" place the red | |
|
|
|
| lead from multimeter on the screw on the terminal block for the | |
|
|
|
| wire you are checking, touch black lead to ground (valve body). | |
|
|
|
| Importantly, a "Zero" volts reading does not automatically indicate | |
|
|
|
| a bad module, there may be too little resistance in the valve sole- | |
|
|
|
| noid. Check the Green wire disconnected from valve that the volt- | |
|
|
|
| age output from the module should be between 2 and 3 volts | |
|
|
|
|
|
|
Exhaust fumes smelled |
| - Fireplace is spilling. | Check all seals. | ||
in room, headaches. |
|
|
|
|
Carbon is being depos- ited on glass, logs or combustion chamber surfaces.
- Air shutter has become | Ensure air shutter opening is free of lint or other obstructions. |
blocked |
|
|
|
- Flame is impinging on the | Check that the logs are correctly positioned. |
logs or combustion chamber. | Open air shutter to increase the primary air. |
| Check the input rate: check the manifold pressure and orifice |
| size as specified by the rating plate values. |
| Check that the door gasketing is not broken or missing and |
| that the seal is tight. |
| Check that both vent liners are free of holes and well sealed |
| at all joints. |
| Check that minimum rise per foot has been adhered to for |
| any horizontal venting. |
Flames are very ag- - Door is ajar | Tighten door clamps | |||
gressive. |
|
|
| |
- Venting action is too great. | Restrict vent exit with restrictor plate. See Restricting Vents. | |||
|
Main burner flame is a blue, lazy, transparent flame.
- Blockage in vent. | Remove blockage. In really cold conditions, ice buildup may occur |
| on the terminal and should be removed as required. |
- Incorrect installation (vertical | Refer to Figure 24 to ensure correct location of storm collars. |
termination only). |
|
White / grey film | - Sulphur from fuel is being de |
forms. | posited on glass, logs or |
| combustion chamber |
| surfaces. |
Clean the glass with a recommended gas fireplace glass cleaner.
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become permanently marked.