18
STOVE VENT CONNECTION
1.Attach the adjustable pipe to the last section of rigid pip- ing. Secure with screws and seal.
2.Install the 4" aluminium flexible liner
to the stove. Secure with 3 screws and flat washers. Seal the joint and screw holes using high temperature sealant.
3.Run a bead of high tem- perature sealant Mill Pac around the inside of the air intake collar. Pull the adjust- able pipe a minimum 2" into the air intake collar.
#8x1/2"
SELF DRILLING SCREWS
SEALANT
ENSURE THAT THE SEAL-
ANT IS NOT VISIBLE ON THE EXTERIOR PIPES ONCE INSTALLATION IS COMPLETED. AN OPTIONAL DECO- RATIVE BRASS BAND IS AVAILABLE FOR THIS USE. (STANDARD WITH A GD175 KIT AND
MOBILE HOME INSTALLATION
In Canada, mobile home installation may be vented horizon- tally or vertically. In the United States, it may only be installed vertically. See "Vertical Venting" or "Horizontal Air Terminal Installation" for installation.
For mobile home installations, the fireplace must be fastened in place. It is recommended that the fireplace be secured in all installations. Use the levelling/securing kit,
RESTRICTING VERTICAL VENTS
FIGURE 27
RESTRICTOR
SHOWN IN A FULLY
OPEN POSITION
Vertical installations may display a very active flame. Loosen the two screws and slide the restrictor plate blocking the ex- haust path. This reduces the velocity of the exhaust gases, slowing down the flame pattern and creating a more traditional flame appearance. For vertical vents greater than 15 feet, this restrictor must be fully closed.
RESTRICTOR |
SHOWN IN A FULLY |
CLOSED POSITION |
GAS INSTALLATION |
1.Install rigid black pipe, or 1/2" type L copper tubing with a
2.Seal and tighten the gas line securely to a flex connec-
tor. | 3/8NPT | FLEXIBLE | SHUT OFF |
|
| CONNECTOR | VALVE |
FIGURE 28 ADAPTERFITTING |
| 1/2FPT | |
|
|
| BLACK |
|
|
| PIPE |
DO NOT KINK FLEXIBLE CONNECTOR.