BLOWER INSTALLATION

Blower (SEE LOCATION AND CLEARANCES)

1.Cut and remove the tie securing the blower switch wires to the heat shield.

2.Connect the white wire coming from below the unit to the terminal on the blower.

3.Connect the black blower wire to the black wire coming from below the unit.

4.Insert the clips on the blower housing into the cutouts in the rear shield. Push down to lock the clips into position.

5.Secure the blower using the screw and lock washer sup- plied.

Note: Ensure that all the wires are tucked into the blower

switch housing.

7 79

8

1 4 4

2

3

5

1 4 4

2

3

5

Switches

6.Open the switch housing by removing the top screw.

7.Install the thermodisc bracket as shown, using 2 of the screws supplied. Connect the flagged leads to the terminals of the thermodisc.

Remove the knock out from the housing label.

8.Install the variable speed switch (rheostat) into the housing with the wires facing up. Secure the switch to the housing using the pal nut and the knob supplied.

9.Connect the male connector on the switch to the female connector coming from the unit.

10.Tuck all of the wires into the housing and close. Secure using the screw removed in step 6.

7 79

8

ACCENT LITE REPLACEMENT

Your Bayfield comes equipped with our “Accent Lite”. If in the event the lamp or lens needs to be replaced, follow these instructions.

Disconnect the two wire leads at the wire nut. Remove the four screws securing the accent lite assembly from the relief door. Disassemble the lite and the lamp now can be accessed

Note: Do not handle the lamp (bulb) with bare fingers, protect with a clean dry cloth.

The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as lamp and lens are special “high RAIL temperature” products.

When re-installing, ensure integrity of gasket seal.

WIRE NUT

SHEILD

COVER PLATE

GASKET

GLASS LENS

GASKET

RELIEF

DOOR RAIL

THE FIREBOX

MUST BE SEALED.

When re-assembling the light assembly, care must be taken with all gaskets.

“Light Leakage” from above the cast doors may be noticed. The holes in the lamp housing are necessary for ventilation and must not be covered.

W415-0547 / B / 05.08.06

Image 7
Contents W415-0547 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts Location & Clearances Stove DimensionsAccent Lite Replacement Blower InstallationAIR Terminal Locations Part Supplier Typical Corner Install With Zero RiseVenting Venting Lengths AIR Terminal LocationsSpecial Vent Installations Typical Vent InstallationsRequired Vertical R I S E I N Feet VT Horizontal TerminationDefinitions Elbow Vent Length ValuesHT + VT Formula 2 HT + VT 24.75 feetHT VT Vertical Termination+ VT =HR + HO = 8 + 5.4 = 13.4 ft = 13.4 + 2.5 = 15.9 ft 3VTVertical Through Existing Chimney InstallationHorizontal Installation Vertical InstallationWall and Ceiling Protection PER Foot Vertical Venting Installation¼ Inch Rise PER Foot Restricting Vertical Vents Mobile Home InstallationGAS Installation Stove Vent ConnectionDoor Latches Cast Front InstallationSwitch Functions FinishingLOG Placement Logo PlacementWire Size MAX. Length Optional Switch / Wiring DiagramTo Turn OFF GAS Operating InstructionsVenturi Adjustment AdjustmentsMaintenance Pilot Injector and Orifice ReplacementReplacements Page Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT SymptomFireplace Service History