2-8 RAC 104 • Installation and Operation

Installation and Operation, cont’d

Your RAC 104 may have shipped with a blue captive screw connector. This blue connector can be plugged into either a blue or an orange power receptacle.

The ideal length of exposed (stripped) copper wire for the blue connector is 3/16" (5 mm).

The blue connector does not have the extended tail or the included tie-wrap.

Do not tin the power supply leads before installing in the direct insertion connector. Tinned wires are not as secure in the connectors and could be pulled out.

After making any adjustments to the RAC 104, either via the front panel controls, SIS commands, or the Extron Audio Products Control Program, wait at least 10 seconds after making those changes before disconnecting power to the RAC 104. Failure to observe the 10-second timeout may result in those adjustments not being saved.