Extron electronic RAC 104 Remote Control, Simple Instruction Set, Host-to-controllerinstructions

Models: RAC 104

1 44
Download 44 pages 28.32 Kb
Page 26
Image 26
Remote Control

Remote Control

The RAC 104 can be controlled remotely via the RS-232 connector using the Extron Simple Instruction Set (SIS) or the Extron Windows-based control program.

The RS-232 connector on the RAC 104 is a 3-pole captive screw connector, with one pole for transmitting data, one for receiving data, and one for the ground. Wire the RS-232 connector as shown below.

Transmit (Tx)

Receive (Rx)

Ground (Gnd, RS-232 connector wiring )

RS-232

Tx Rx

RS-232 connector wiring

Pin

RS-232 functionDescription

 

 

 

1

Tx

Transmit data

2

Rx

Receive data

3

Gnd

Signal ground

 

 

 

RS-232 pin assignment table

The RS-232 protocol for this connector is 9600 baud, 8-bit, 1 stop bit, no parity.

Simple Instruction Set

Host-to-controller instructions

The RAC 104 accepts SIS commands through the RS-232 port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each controller response to an SIS command ends with a carriage return and a line feed (CR/LF = RS-232 function ), which signals the end of the response character string. A string is one or more characters.

Controller-initiated messages

The following copyright message is initiated by the controller when it is first powered on. Vx.xx is the firmware version number.

Boot V1.00,(c) 2003, ? to Enter

(c) Copyright 2003,Extron Electronics,RAC 104, Vx.xxDescription

3-2 RAC 104 • Remote Control
Page 26
Image 26
Extron electronic RAC 104 Remote Control, Simple Instruction Set, Host-to-controllerinstructions, RS-232connector wiring