3 = group B, channel 3

4 = group B, channel 4

X3 = 0 or 1

0 = off

1 = on

X4 = 0 through 14, bass adjustment range (+/-14 dB; 2 dB increment/decrement, bass in dB = [bass number minus 7] times 2; default = 7 [0 dB]).

X5 = 0 through 14, treble adjustment range (+/-14 dB; 2 dB increment/decrement, treble in dB = [treble number minus 7] times 2; default = 7 [0 dB]).

X6 = Front panel executive modes

0 = off

1 = executive mode 1

2 = executive mode 2

 

 

X7

 

= Controller software version to second decimal place

 

 

 

 

 

= A or B, group number

 

 

 

 

 

 

 

 

 

 

 

 

X8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group A = channels 1 and 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group B = channels 3 and 4

 

 

 

 

 

 

 

 

 

 

= 1 through 3, preset number

 

 

 

 

 

 

 

 

 

X9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= -12 through +12 (audio gain or attenuation in dB)

 

 

 

 

X10

 

 

 

 

 

 

 

 

 

= 0 through 12 (audio gain in dB)

 

 

 

 

 

 

 

 

 

X11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= 1 through 12 (audio attenuation in dB)

 

 

 

 

 

 

 

X12

 

 

 

 

 

 

 

 

 

 

 

 

= 0 through 15, decimal number indicates settings for the

 

 

X13

 

 

 

 

 

 

 

 

 

 

four input and output line level DIP switches. DIP

 

 

 

 

 

 

 

 

 

switch settings are shown in the table below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

Group

 

 

0

1

2

3

4

5

6

7

 

8

9

10

11

12

13

14

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Input A

Off

Off

Off

Off

Off

Off

Off

Off

 

On

On

On

On

On

On

On

On

2

Input B

Off

Off

Off

Off

On

On

On

On

 

Off

Off

Off

Off

On

On

On

On

3

Output A

Off

Off

On

On

Off

Off

On

On

 

Off

Off

On

On

Off

Off

On

On

4

Output B

Off

On

Off

On

Off

On

Off

On

 

Off

On

Off

On

Off

On

Off

On

Off = -10 dBV (unbalanced, consumer level)

On = +4 dBu (balanced, pro level)

3-4