Extron electronic RAC 104 ASCII Command, Response, Additional description, System reset

Models: RAC 104

1 44
Download 44 pages 28.32 Kb
Page 31
Image 31
View Preset Settings

Command

ASCII Command

Response

Additional description

 

(host to RAC 104)

(RAC 104 to host)

 

View Preset Settings

 

 

 

View input gain

View output volume

View bass setting

View treble setting

X2 * X9 *5#

X2 * X9 *6#

X2 * X9 *7#

X2 * X9 *8#

X10System resetUpdate firmware

X1Manual backgroundManual background

X4Manual backgroundManual background

X5Manual backgroundManual background

System reset

Reset to factory defaults

Esc ZXXX

 

Zpx

Default settings:

 

 

 

 

Input gain X10 = 0

 

 

 

Volume level X1 = 70

 

 

 

Bass level X4 = 7

 

 

 

Treble level X5 = 7.

RAC 104 • Remote Control 3-7

Update firmware

Upload firmware update

Esc Upload

 

Go

See note below.

 

Upload success

 

 

UPL

See note below.

Firmware updates will periodically become available on the Extron Web site. To update the firmware, first download the update file from the site. Then open HyperTerminal and type the Esc UploadManual background command.

After receiving the GoManual background response, select Send Text File from the Transfer menu. In the Send Text File window, locate and select the file you downloaded and click Open. The controller will send the UPLManual background response once the update has been successfully completed. It will send the error code E23 if the update failed.