Error responses

When the interface receives a valid SIS command, it executes the command and sends a response to the host device. If the interface is unable to execute the command because the command is invalid or it contains invalid parameters, it returns an error response to the host.

The error response codes and their descriptions are as follows:

E10 – Invalid command

E13 – Invalid value (the number is out of range/too large)

Timeout

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The command operation is aborted with no other indication.

Using the command/response table

The command/response table is on the next page. Lower case letters are allowed in the command field only as indicated. Symbols are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table. The ASCII to HEX conversion table below is for use with the command/response table.

Symbol definitions

] = CR/LF (carriage return/line feed) (0x0D 0A)

= space

X@

=

Shift control range

-127 to +127

X#

= Controller firmware version (listed to two decimal

 

 

 

places, “x.xx”)

X$

=

xxx.xx

Frequency in Hz or kHz

X^

=

Part number

 

ASCII to HEX Conversion Table