RGB 201 Rxi Universal Interface • Remote Control
Remote Control, cont’d
3-4
Command/response table for SIS commands
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Horizontal shift
Set horizontal shift X@ H Hph X@] Set horizontal shift value to X@ (range -127 to +127).
Example: 28H Hph+028] Set horizontal shift value to +28.
Increment horizontal shift value +H HphX@] Previous horizontal shift value +1 (shift right).
Decrement horizontal shift value -H HphX@] Previous horizontal shift value -1 (shift left).
View horizontal shift value H X@]
Vertical shift
Set vertical shift X@ / VphX@ Set vertical shift value to X@ (range -127 to +127).
Example: -5/ Vph-005] Set horizontal shift value to -5.
Increment vertical shift value +/ VphX@] Previous vertical shift value +1 (shift up).
Decrement vertical shift value -/ VphX@] Previous vertical shift value -1 (shift down).
View vertical shift value / X@]
View, information, part number, and rmware requests
Information request I/i HphX@•VphX@•HrtX$•VrX$]
Example Hph+028•Vph-005•Hrt48.400•Vrt60.000]
Horizontal shift value +28; vertical shift value -5;
horizontal rate 48.4 kHz; vertical rate 60 Hz.
Request for part number N/n X^]
Example: n 60-507-01] 60-507-01 = RGB 201 Rxi.
Query software version Q/q X#]
Example: q 1.23] Software version 1.23 (example only).