3-4 RGB

Command/response table for SIS commands

Command

ASCIICommand

Response

Additional description

 

(host to switcher)

(switcher to host)

 

 

 

 

 

Remote

201 Rxi Universal

Horizontal shift

Set horizontal shift

X@H

Hph X@]

Example:

28H

Hph+028]

Increment horizontal shift value

+H

HphX@]

Decrement horizontal shift value

-H

HphX@]

View horizontal shift value

H

X@]

Set horizontal shift value to X@(range -127 to +127). Set horizontal shift value to +28.

Previous horizontal shift value +1 (shift right). Previous horizontal shift value -1 (shift left).

Control, cont’d

Interface • Remote

Vertical shift

Set vertical shift

X@/

VphX@

Example:

-5/

Vph-005]

Increment vertical shift value

+/

VphX@]

Decrement vertical shift value

-/

VphX@]

View vertical shift value

/

X@]

Set vertical shift value to X@ (range -127 to +127). Set horizontal shift value to -5.

Previous vertical shift value +1 (shift up). Previous vertical shift value -1 (shift down).

Control

View, information, part number, and firmware requests

Information request

I/i

HphX@•VphX@•HrtX$•VrX$]

 

Example

 

Hph+028•Vph-005•Hrt48.400•Vrt60.000]

 

 

 

Horizontal shift value +28; vertical shift value -5;

 

 

X^]

horizontal rate 48.4 kHz; vertical rate 60 Hz.

Request for part number

N/n

 

Example:

n

60-507-01]

60-507-01 = RGB 201 Rxi.

Query software version

Q/q

X#]

 

Example:

q

1.23]

Software version 1.23 (example only).

Page 36