Internal Configuration
The interface is factory configured to output RGBHV or RGBS video whose sync follows the input and that is clamped to the back porch. The interface can be configured to output positive or negative sync, output RsGsBs video, or to clamp on the sync tip. All of these reconfigurations require opening the interface’s case.
1. Remove the three screws on each side and the two screws on top of the cover (figure
Slide cover back slightly, lift straight up.
LEVEL |
|
|
| PEAK |
|
BOOST |
| CENTERING |
| CONTROL | |
|
|
R |
|
|
GB |
|
|
20 | 1Rxi |
|
| WITHA | |
|
| DSPTM |
Remove (8 ) Screws
Figure 2-1 — Opening the interface
2. Move the cover back slightly to clear the BNC connectors and then lift it away carefully to avoid straining any cables.
3. Configure the interface as desired. See Sync polarity jumpers, Internal sync DIP switches (RsGsBs), and Video clamping jumper in this chapter. Figure
4. Replace the cover and reinstall the screws.
RGB 201 Rxi Universal Interface • Installation and Operation |