6
LOCATION & CLEARANCES
Provide adequate accessibility clearance for
servicing and operating the stove.
Never obstruct the front opening of the stove.
*AT A DISTANCE OF 2" FROM THE WALL, INSTALLATION OR SERVICE TO THE BLOWER MAY NOT BE PRACTICAL. A MINIMUM OF 5" WILL BE REQUIRED IN ORDER TO INSTALL THE BLOWER.
As long as clearance to combustibles is kept within the re- quired distances, the most desirable and beneficial location for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The loca- tion of windows, doors and the traffic flow in the room where the stove is to be located should be considered. If possible, you should choose a location where the vent will pass through the house without cutting a floor or roof joist.
STOVE DIMENSIONS
FIGURE 1
17 1/2"
7" DIA. | 4" DIA. |
25 5/8" | 23 5/8" |
12 3/4"
23 1/2"
MAINTAIN THESE MINIMUM CLEARANCES MANTEL OR SHELF CLEARANCES: TO COMBUSTIBLES:
COMBUSTIBLE | 12” |
MANTEL OR TRIM | MAX. MANTEL WIDTH |
MATERIAL |
|
8” |
|
MIN. |
|
A. 4" | B. 2"* | C. 2" | FIGURE 2 |
STOVE SHOULD NOT BE INSTALLED DIRECTLY ON CARPETING. MINIMUM 48" FROM STOVE TOP TO CEILING
TO CEILING FROM STOVE TOP | 48" |
HORIZONTAL VENT | 1" |
SIDES AND BOTTOM | |
TOP | 2" |
VERTICAL VENT | 1" |
ALL SIDES |
*AT A DISTANCE OF 2" FROM THE WALL, INSTALLATION OR SERVICE TO THE BLOWER MAY NOT BE PRACTICAL. A MINIMUM OF 5" WILL BE REQUIRED IN ORDER TO INSTALL THE BLOWER.
If less than 5" clearance is maintained between the back of the stove and the back wall, it will be necessary to disconnect the venting and gas pipe to move the stove out for installation or service of the blower.
When the |
|
fireplace is rear |
|
vented, a mantel |
|
or shelf may be |
|
installed above |
|
the GDS25 at a |
|
minimum | 2” |
distance of 8". |
COMBUSTIBLE MATERIALS