Napoleon Fireplaces GDS25N GDS25P manual Formula 2 HT + VT 24.75 feet, Ht + Vt

Page 12

12

HORIZONTAL TERMINATION

when (HT) > (VT)

Simple venting configuration (only one 45º and 90° elbow)

See graph to determine

the required vertical rise VTFIGURE 7 for the required horizontal

run HT.

Example 2:

90°

 

90°

FIGURE 8

H3

H1

H4

 

 

 

45°

 

H2

V2

 

 

 

90°

 

V1

 

 

 

 

 

 

150

 

 

 

 

 

 

140

 

 

 

V1

= 4 ft

REQUIRED

 

 

 

 

130

 

 

 

V2

= 1.5 ft

 

 

 

 

 

 

VERTICAL

120

 

 

 

VT

= V1 + V2 = 4 ft + 1.5 ft = 5.5 ft

RISE IN

110

 

 

 

H1

= 2 ft

INCHES (VT)

 

 

 

100

 

 

 

H2

= 1 ft

 

 

 

 

 

90

 

 

 

H3

= 1 ft

 

 

 

 

H4

= 1.5 ft

 

 

 

 

 

 

80

 

 

 

HR

= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft

 

70

 

 

 

HO

= .03(one 45º elbow + three 90º elbow -135º)

 

60

 

 

 

 

=.03(315-135)=5.4ft

 

 

 

 

HT

= HR + HO = 5.5 +5.4 = 10.9 ft

 

50

 

 

 

 

 

 

 

HT + VT

= 10.9 + 5.5 = 16.4 ft

 

40

 

 

 

 

 

 

 

Formula 1: HT < 4.2 VT

 

30

 

 

 

 

 

 

 

 

4.2 VT = 4.2 x 5.5 = 23.1 ft

 

20

 

 

 

 

 

 

 

 

 

10.9 < 16.8

 

10

 

 

 

 

 

 

 

 

Formula 2: HT + VT < 24.75 feet

 

0

5

10

15

 

20

16.4 < 24.75

HORIZONTAL VENT RUN PLUS OFFSETS IN FEET

 

 

 

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than one 45º and 90° elbow the following formulas apply:

Formula 1: HT < 4.2 VT

Formula 2: HT + VT < 24.75 feet

Since both formulas are met, this vent configuration is acceptable.

W415-0547 / B / 05.08.06

Image 12
Contents W415-0547 / B What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Stove Dimensions Location & ClearancesBlower Installation Accent Lite ReplacementAIR Terminal Locations Typical Corner Install With Zero Rise VentingVenting Lengths AIR Terminal Locations Part SupplierTypical Vent Installations Special Vent InstallationsHorizontal Termination DefinitionsElbow Vent Length Values Required Vertical R I S E I N Feet VTFormula 2 HT + VT 24.75 feet HT + VTVertical Termination HT VT3VT + VT =HR + HO = 8 + 5.4 = 13.4 ft = 13.4 + 2.5 = 15.9 ftInstallation Vertical Through Existing ChimneyVertical Installation Horizontal InstallationWall and Ceiling Protection Vertical Venting Installation PER Foot¼ Inch Rise PER Foot Mobile Home Installation GAS InstallationStove Vent Connection Restricting Vertical VentsCast Front Installation Switch FunctionsFinishing Door LatchesLogo Placement LOG PlacementOptional Switch / Wiring Diagram Wire Size MAX. LengthOperating Instructions To Turn OFF GASAdjustments MaintenancePilot Injector and Orifice Replacement Venturi AdjustmentReplacements Page Trouble Shooting Guide Symptom Problem Test SolutionSymptom Do not Clean Glass When HOTFireplace Service History