Vermont Casting SNV30 manual Paint Option for Enamelled Stoves, Connect the Gas Supply Line

Page 10

Stardance Natural Vent Gas Heater

Insert the B-vent adapter into the flue collar and drill 1/8” (3mm) pilot holes through both the stove’s collar and the adapter. Attach the adapter to the flue collar with sheet metal screws. (Fig. 15)

Attach the first section of venting to the B-vent adapter. Depending on the length of the individual venting sections and the lengths of the decorative pipe, you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be fastened at each joint, other than slip sections. The decorative pipe need not be fastened to the locating bracket on the stove. If the layout includes a slip section, this should be the last section of pipe vis- ible in the room at the ceiling. Refer to Page 7, Figure 6

for details on joining the decorative pipe at the ceiling.

ST373

Fig. 15 Attach the B-vent adapter to the flue.

B-vent Pipe

Decorative

Pipe 7FSSK

Bracket

ST374

Fig. 16 Install decorative pipe over the B-vent pipe.

Paint Option for Enamelled Stoves

If you wish to match the decorative or vent pipe to the color of the stove, paint the pipe before installation. Use only a high-temperature paint. Paint only in a well-venti- lated area. Mask the surroundings to prevent overspray. Apply the paint lightly; two light coats will result in a better finish than a single heavy coat. Let the paint dry thoroughly before handling painted parts.

Connect the Gas Supply Line

Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Stardance may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on Page 24.

CAUTION

This appliance should only be connect- ed by a qualified gas technician. Test to confirm manifold pressures as specified

below.

The Stardance Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

The Stardance Heater must be isolated from the gas supply piping system by closing its indi- vidual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.

There must be a gas shutoff between the stove and the supply.

In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 28,000 BTUs at a manifold pressure of 3.5” and a minimum inlet supply pressure of 5.5” w.c.

In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” pro- pane gas supply line with an input of 26,000 BTUs at a manifold pressure of 10.0” and a mini- mum inlet supply pressure of 11.0” w.c.

In the U.S.; Gas connection should be made in ac- cordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult you local authority.

In Canada; consult the local authority and CSA-B149.1 installation code.

Connect the gas supply and test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame. Light the pilot according to the directions on Page 14, before going to the next step.

1010

20007067

Image 10
Contents Stardance Natural Vent Gas Heater Table of Contents General Information Stardance Natural Vent Gas Heater Dimensions Stardance dimensionsCorner Installation Minimum Clearance Flue Centerline Parallel Installation Minimum Clearance Flue CenterlineAlcove Minimum Dimensions Ceiling ClearancesHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Venting Requirements and OptionsPassing Through a Combustible Wall or Ceiling Venting RequirementsInstall the Optional Fan InstallationUnpack the Stove Venting System Assembly Attach rheostat to left side of valvePaint Option for Enamelled Stoves Connect the Gas Supply LineBurner Information Install ON/OFF SwitchInstall the Log Set Thermostat Connection optionalInstall the Front Plate This completes assembly of the Stardance stoveOperation Flame & Temperature AdjustmentFlame Characteristics Your First FireTo Turn Off Gas To Heater What to do if YOU Smell GASTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionFuel Conversion Instructions Conversion PrecautionsConversion Procedure Valve Conversion Honeywell ValvePilot Orifice Conversion Remove pilot hoodConversion to Natural Gas Input BTU/h Air Shutter Injector Orifice Size MatrixConversion to LP Input BTU/h Air Shutter Maintenance Inspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyWiring Diagrams BLKStardance Natural Vent Gas Heater SNV30 DescriptionStardance Natural Vent Gas Heater SNV30 SNV30Fuel Conversion Kits Fan Kits Optional Accessories AvailableRemote Controls Screen KitOutside Air Adapter Warming ShelfDecorative Rings Model ColorStardance Natural Vent Gas Heater 2828 Stardance Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Garantie DE BaseEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %