Vermont Casting SNV30 manual Pilot Orifice Conversion, Remove pilot hood

Page 17

A

B

C

 

OFF

 

P

 

 

I

O

TO

L

 

FC107

Fig. 30 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly.

E

Stardance Natural Vent Gas Heater

Pilot Hood

Pilot

Bracket

CO105a

Fig. 32 Remove pilot hood.

Index Tab

Allen Wrench

 

Snap Ring

 

CO106a

 

Fig. 33 Remove pilot orifice.

O

F

OFF

P

I TOL

D

FC108

is set at 1/8” or 3/8” opening depending on rating plate serial number. To convert to natural gas, the shutter should set to fully closed. Refasten the two nuts. (Fig. 35)

NOTE: Be sure burner leg remains at a 90° angle to firebox base after conversion.

3/8"

Fig. 31 Replace regulator.

3.Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 31)

Pilot Orifice Conversion

14.Locate pilot. (Fig. 28)

15.Replace pilot orifice.

Remove pilot hood by lifting up. (Fig. 32) NOTE: It is not necessary to remove the pilot tube for conversion.

Remove pilot orifice with allen wrench. (Fig. 33)

Install the conversion orifice.

Reinstall pilot hood. Be sure to align hood with index tab.

16.Adjust air shutter on the burner. The air shutter is located on the bottom of the burner on the left. (Fig. 34) Loosen the two nuts holding the shutter in place. On natural gas units, the shutter is shipped fully closed. To convert to LP, reset the shutter as speci- fied in Table 2. (Fig. 35) On propane unit the shutter

Air Shutter

(LP Position)

ST785

Fig. 34 LP air shutter settings.

Front Injector

Burner

Air Inlet

 

Rear

 

Injector

 

Air Inlet

 

Covered

Air Shutter

 

ST784

Fig. 35 Natural gas air shutter setting.

20007067

17

Image 17
Contents Stardance Natural Vent Gas Heater Table of Contents General Information Stardance dimensions Stardance Natural Vent Gas Heater DimensionsAlcove Minimum Dimensions Parallel Installation Minimum Clearance Flue CenterlineCorner Installation Minimum Clearance Flue Centerline Ceiling ClearancesGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Venting Requirements and OptionsVenting Requirements Passing Through a Combustible Wall or CeilingUnpack the Stove InstallationInstall the Optional Fan Attach rheostat to left side of valve Venting System AssemblyConnect the Gas Supply Line Paint Option for Enamelled StovesInstall the Log Set Install ON/OFF SwitchBurner Information Thermostat Connection optionalThis completes assembly of the Stardance stove Install the Front PlateFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireWhat to do if YOU Smell GAS To Turn Off Gas To HeaterSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Procedure Conversion PrecautionsFuel Conversion Instructions Valve Conversion Honeywell ValveRemove pilot hood Pilot Orifice ConversionConversion to LP Input BTU/h Air Shutter Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Air Shutter Maintenance Stove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyBLK Wiring DiagramsDescription Stardance Natural Vent Gas Heater SNV30SNV30 Stardance Natural Vent Gas Heater SNV30Fuel Conversion Kits Remote Controls Optional Accessories AvailableFan Kits Screen KitDecorative Rings Warming ShelfOutside Air Adapter Model ColorStardance Natural Vent Gas Heater 2828 Stardance Natural Vent Gas Heater Product Covered by this Warranty Limited Lifetime WarrantyGarantie DE Base SI UN Service Sous Garantie EST REQUIS…Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings