Vermont Casting SNV30 Burner Information, Install ON/OFF Switch, Thermostat Connection optional

Page 11

Burner Information

The appliance must only use the gas specified on the rating plate, unless converted using a Fuel Conversion Kit. Refer to Page 25 for the correct Fuel Conversion Kit for your model.

Conversion instructions are provided with each kit and

beginning on Page 16 in this manual.

THIS APPLIANCE SHOULD BE CON- NECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES.

THERE MUST BE A GAS SHUT-OFF BE- TWEEN THE STOVE AND THE SUPPLY.

In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 28,000 BTUs at a manifold pressure of 3.5” and a minimum inlet supply pressure of 5.5” w.c.

In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 26,000 BTUs at a manifold pressure of 10.0” and a minimum inlet supply pressure of 11.0” w.c.

Install ON/OFF Switch

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 17)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 18)

Switch As-

semblyExisting Holes

Screws

ST315

Fig. 17 Attach switch assembly to rear shroud.

Stardance Natural Vent Gas Heater

PILOT

 

ADJ

 

TPTH

 

TP

 

TH

ST228

 

Fig. 18 Attach switch wires to valve.

Thermostat Connection (optional)

Use only a thermostat rated for 500 - 750 millivolts.

Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation.

Thermostat

 

Wire / Gauge

Maximum Run

18

40 feet

20

25 feet

22

16 feet

1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.

2.Connect the thermostat wires to the valve. (Fig. 18)

Install the Log Set

NOTE: The bracket shipped with logs is for fan installa- tion only.

1.Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAM-

AGED LOGS.

2.Install the rear log centering it side to side on the sheet metal shelf at the back of the firebox. (Fig. 19) The log will touch both sides and the back wall of the firebox.

3.Install the right log by engaging hole on bottom with pin on the rear log. (Fig. 19) Then set right bottom side on the burner so the edge of the log touches the right side of the firebox. The right log does not use the locator pins on the burner to stay in place.

4.Install the left log by engaging hole on bottom with pin on rear log. (Fig. 21) Then set left bottom side on the burner so the edge of the log touches the left side of the firebox.

5.Loosely sprinkle the lava rocks directly on top of the burner in front of and between the decorative grate and the right and left logs. Use the lava rock to cover brackets on the burner. (Fig. 20)

20007067

11

Image 11
Contents Stardance Natural Vent Gas Heater Table of Contents General Information Stardance dimensions Stardance Natural Vent Gas Heater DimensionsCeiling Clearances Parallel Installation Minimum Clearance Flue CenterlineAlcove Minimum Dimensions Corner Installation Minimum Clearance Flue CenterlineVenting Requirements and Options Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsVenting Requirements Passing Through a Combustible Wall or CeilingUnpack the Stove InstallationInstall the Optional Fan Attach rheostat to left side of valve Venting System AssemblyConnect the Gas Supply Line Paint Option for Enamelled StovesThermostat Connection optional Install ON/OFF SwitchInstall the Log Set Burner InformationThis completes assembly of the Stardance stove Install the Front PlateYour First Fire Flame & Temperature AdjustmentFlame Characteristics OperationWhat to do if YOU Smell GAS To Turn Off Gas To HeaterSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemValve Conversion Honeywell Valve Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsRemove pilot hood Pilot Orifice ConversionConversion to LP Input BTU/h Air Shutter Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Air Shutter Maintenance Check the Gas Flame Regularly Gasket ReplacementStove Disassembly Inspect the Vent System AnnuallyBLK Wiring DiagramsDescription Stardance Natural Vent Gas Heater SNV30SNV30 Stardance Natural Vent Gas Heater SNV30Fuel Conversion Kits Screen Kit Optional Accessories AvailableRemote Controls Fan KitsModel Color Warming ShelfDecorative Rings Outside Air AdapterStardance Natural Vent Gas Heater 2828 Stardance Natural Vent Gas Heater Product Covered by this Warranty Limited Lifetime WarrantyGarantie DE Base SI UN Service Sous Garantie EST REQUIS…Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings