Vermont Casting SNV30 manual Installation, Unpack the Stove, Install the Optional Fan

Page 8

Stardance Natural Vent Gas Heater

Installation

Unpack the Stove

The Stardance is shipped fully assembled on its back. Unpack the stove and carefully set it upright.

CAUTION

Porcelain enamelled surfaces are fragile. Handle porcelain enamelled castings tenderly. Familiarize yourself with the assembly steps before you begin and proceed with deliberation and care. If possible, have assistance available.

Place enamelled castings on a soft, cushioned sur- face until you are ready to assemble.

Avoid contact between the castings and other hard surfaces or objects.

Install the Optional Fan

WARNING

This appliance is equipped with a three-prong (grounded) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a fan kit, proceed to Venting System Assembly.

1.The fan kit includes a blower assembly and a rheo- stat assembly, connected by a cable. The blower as- sembly mounts to the bottom rear of the stove, and the rheostat mounts to the left side of the valve. The assembly includes a ‘snapstat’ which automatically turns the fan ON (or OFF) above (or below) approxi- mately 109°F. The rheostat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High. Unpack and inspect the blower assembly. Confirm that the fan spins freely.

2.Remove the rear shroud by loosening the two (2) bolts at the bottom left and right side of the shroud. Slide shroud straight up, rotate the bottom out and away from stove and pull shroud out.

3.Attach the fan assembly to the fan bracket provided in the log box. Use #10 sheet metal screws provided in fan kit. Do not remove finger guard screws. (Fig.

8)

Snapstat

Wire

Rheostat Wire

Fan Bracket

ST669

Finger Guard

Fig. 8 Attach the fan assembly to the fan bracket.

4.Connect snapstat leads. Disconnect the snapstat module from the leads inside the snapstat bracket. (Fig. 9) Bend open the snapstat bracket. Use needle nose pliers to remove the black plastic grommet from the bracket. Discard the bracket. Connect

the two wires to the two snapstat extension leads located between the inner and outer shroud.

Snapstat Bracket

Snapstat Module

Pinch

Grommet to

Remove

ST670

Fig. 9 Remove the snapstat and grommet from the bracket

5.Position the fan assembly so the ducts slide be- tween the inner and outer shroud. The inner shroud should engage with the two slots in the ends of the bracket so the bracket and shroud are interlocked. (Fig. 10) Secure the bracket with the four sheet metal screws provided in the finish bag.

6.Install the snapstat by loosening the front screw on the inner side of the duct. (Fig. 11) Slide the snapstat under the head of the screw and tighten. Connect the leads to the snapstat. Make sure the snapstat assembly is mounted straight front to back.

7.Reattach rear shroud assembly in reverse order of Step 2. Tighten bottom bolts to hold shroud in place.

88

20007067

Image 8
Contents Stardance Natural Vent Gas Heater Table of Contents General Information Stardance Natural Vent Gas Heater Dimensions Stardance dimensionsParallel Installation Minimum Clearance Flue Centerline Alcove Minimum DimensionsCorner Installation Minimum Clearance Flue Centerline Ceiling ClearancesGas Specifications Gas Inlet and Manifold PressuresHigh Elevations Venting Requirements and OptionsPassing Through a Combustible Wall or Ceiling Venting RequirementsUnpack the Stove InstallationInstall the Optional Fan Venting System Assembly Attach rheostat to left side of valvePaint Option for Enamelled Stoves Connect the Gas Supply LineInstall ON/OFF Switch Install the Log SetBurner Information Thermostat Connection optionalInstall the Front Plate This completes assembly of the Stardance stoveFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireTo Turn Off Gas To Heater What to do if YOU Smell GASTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionConversion Precautions Conversion ProcedureFuel Conversion Instructions Valve Conversion Honeywell ValvePilot Orifice Conversion Remove pilot hoodConversion to LP Input BTU/h Air Shutter Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Air Shutter Maintenance Gasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKStardance Natural Vent Gas Heater SNV30 DescriptionStardance Natural Vent Gas Heater SNV30 SNV30Fuel Conversion Kits Optional Accessories Available Remote ControlsFan Kits Screen KitWarming Shelf Decorative RingsOutside Air Adapter Model ColorStardance Natural Vent Gas Heater 2828 Stardance Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Garantie DE BaseEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %