Vermont Casting SNV30 Fuel Conversion Instructions, Conversion Precautions, Conversion Procedure

Page 16

Stardance Natural Vent Gas Heater

Fuel Conversion Instructions

WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- tions is not followed exactly, a fire, explosion

or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is respon- sible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before pro- ceeding with the conversion.

 

 

OFF

 

I

 

 

H O

NO

 

 

TPILOJAD

 

 

Main

 

 

Gas Line

 

Gas Supply Inlet

 

 

ST226

Fig. 27

Attach the gas line to the left side of the valve.

Conversion Precautions

Conversion must be completed only by qualified personnel. Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAU-

6.Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 28)

7.Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.

Remove

Loosen Screw

 

Rear Log Bracket

Screws

 

 

 

 

Pilot

 

Left & Right Log

ST350

 

Bracket Assembly

Fig. 28 Remove rear log bracket and left and right log bracket assembly.

8.Remove injector orifices from left burner leg using 1/2” wrench. (Fig. 34)

9.Install conversion orifices. (Refer to Table 2)

Valve Conversion Honeywell Valve

1.Remove cap from Hi-Lo knob. This can be accom- plished by lifting the plastic cap off the screw. (Fig. 29)

2.Remove the screw from center of Hi-Lo knob with small screwdriver turning counterclockwise. (Fig. 29)

3.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.

4.Tighten screw (do not over tighten), replace cap.

TION: Allow stove to cool completely before beginning conversion.

Conversion Procedure

1. Remove stove front. Lift stove front up and then

swing bottom out and away to disengage from the

stove body. (Page 19, Fig. 35)

Cap

HI

LO

Hi-Lo

Knob

Lift Open

HI

LO

Center Screw CO100

2.

Swing open the swiveling latches at the top left and

 

right corners of the glass frame. (Page 20, Fig. 36)

3.

Pull the top edge of the glass and frame assembly

 

away from the firebox face. Place the assembly out

 

of the way on a flat, padded surface such as a coun-

 

ter protected by a towel.

4.

Remove the logset from the firebox.

5.

Remove the rear log bracket by loosening the screw

 

and sliding the bracket up. CAUTION: Do not re-

 

move the screw completely. It would be very difficult

to replace. (Fig. 28)

1616

Fig. 29 Remove center screw from Hi-Lo knob.

SIT 820 Valve

1.Using TORX T20 bit, remove and discard the three

(3) pressure regulator mounting screws (A), pres- sure regulator tower (B) and the spring and dia- phragm assembly (C). (Fig. 30)

2.Insure the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assem- bly to the valve using the new screws (E) supplied with the kit. Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 31)

20007067

Image 16
Contents Stardance Natural Vent Gas Heater Table of Contents General Information Stardance Natural Vent Gas Heater Dimensions Stardance dimensionsParallel Installation Minimum Clearance Flue Centerline Alcove Minimum DimensionsCorner Installation Minimum Clearance Flue Centerline Ceiling ClearancesGas Specifications Gas Inlet and Manifold PressuresHigh Elevations Venting Requirements and OptionsPassing Through a Combustible Wall or Ceiling Venting RequirementsInstall the Optional Fan InstallationUnpack the Stove Venting System Assembly Attach rheostat to left side of valvePaint Option for Enamelled Stoves Connect the Gas Supply LineInstall ON/OFF Switch Install the Log SetBurner Information Thermostat Connection optionalInstall the Front Plate This completes assembly of the Stardance stoveFlame & Temperature Adjustment Flame CharacteristicsOperation Your First FireTo Turn Off Gas To Heater What to do if YOU Smell GASTroubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionConversion Precautions Conversion ProcedureFuel Conversion Instructions Valve Conversion Honeywell ValvePilot Orifice Conversion Remove pilot hoodConversion to Natural Gas Input BTU/h Air Shutter Injector Orifice Size MatrixConversion to LP Input BTU/h Air Shutter Maintenance Gasket Replacement Stove DisassemblyInspect the Vent System Annually Check the Gas Flame RegularlyWiring Diagrams BLKStardance Natural Vent Gas Heater SNV30 DescriptionStardance Natural Vent Gas Heater SNV30 SNV30Fuel Conversion Kits Optional Accessories Available Remote ControlsFan Kits Screen KitWarming Shelf Decorative RingsOutside Air Adapter Model ColorStardance Natural Vent Gas Heater 2828 Stardance Natural Vent Gas Heater Limited Lifetime Warranty Product Covered by this WarrantySI UN Service Sous Garantie EST REQUIS… Garantie DE BaseEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %