Maintenance

Let the fire in the stove go out and allow the stove to cool completely before beginning any maintenance procedure.

Care of the Cast Iron Surface

An occasional dusting with a dry rag will keep the painted cast iron of your Intrepid looking new.

The stove’s paint can be touched up as needed. First, clean the areas to be painted with a wire brush. Re- move the griddle and set it aside. Then, touch up the stove with Vermont Castings high temperature stove paint. Apply the paint sparingly, and keep in mind that two light coats of paint are better than a single heavy one.

Care of Porcelain Enamel Finish

Use a dry or slightly damp rag or a soft brush to remove spills or stains. For difficult jobs that require a cleaning agent, use only a kitchen appliance cleaner or polish recommended for use on enamel surfaces.

Cleaning the Glass

Most of the carbon deposits on the glass will burn off during hot fires. However, the ash residue that accumu- lates on the glass surface should be removed regularly to prevent etching. Follow this procedure to clean the glass:

Be sure the glass is completely cool.

Clean the glass with water or a cleaner made espe- cially for this purpose. Do not use abrasive cleaners.

Rinse the glass thoroughly.

Dry the glass completely.

Glass Replacement

The panes of glass in the doors of the Intrepid rest on a cushion of gasket, and are held in place by four clips. The glass is coated on one side. The coated side is slightly colored and is further identified with white labels marked “CV+”. Remove the doors from the stove and place them on a sturdy, level work surface. To install the glass, follow this procedure:

1.Remove the door. Swing the door back and forth while lifting it, to remove its hinges from the stove front. Set the door down on a flat, padded surface. Remove the clips and the broken glass; set them aside.

2.Inspect the Gasket. If the window gasket is in good condition, you can leave it in place. If you replace it, use only a Vermont Castings gasket, part no. 1203556. Be sure the channel around the window opening is clean and free of dust.

Place the gasket in its channel; make sure that its outer edge fits against the cast iron surround ridge.

3.Install the glass. Lay the glass on the inner gasket with the coated side down (toward the outside of the door). Tighten the screws snugly, but loose enough to allow for a little movement of the glass when the stove is in operation. Overtightening can crack the glass immediately or cause it to crack if it is unable to expand when hot.

 

Gasket

KT160

 

 

Fig. 39

Door glass installation.

 

Check the Operation of the

Primary Air Shutter

The primary air shutter is visible from the back of the stove. The shutter must open and close freely when you move the thermostat lever. If it does not, check for any obstruction, or for a bound or stretched chain need- ing adjustment. (Fig. 40)

On a cold stove the shutter should be open no more than 1/8” (3mm) when the primary air control lever is pushed completely to the left (closed), as seen from the back of the stove. When the lever is pushed completely to the right (open), the shutter should be open to an angle of approximately 70 degrees from the stove back.

The ball chain should measure 8¹⁄₂” (216 mm) from connection to the thermostat coil to connection on the primary air flap.

If setting is incorrect, the thermostat coil may be bent or broken. Call you Vermont Castings Dealer for help.

2000970

25

Image 25
Contents Intrepid Welcome Table of ContentsIntrepid Multi-Fuel, Model 1695, 1696 SpecificationsOutside Air InstallationWhat Kind of Chimney to Use Masonry Chimneys Chimney Connector GuidelinesPrefabricated Chimneys Chimney SizeSingle-wall Chimney Connector Double-wall Chimney ConnectorSecuring the Single-wall Connector to a Masonry Chimney Freestanding Chimney InstallationsFireplace Chimney Installations Through a Fireplace Fireplace Chimney Installations Above a FireplaceAn approved wall pass-through for the United States Wall Pass-ThroughsFloor Protection Floor Protection for Fireplace InstallationsReducing Clearances Chimney Connector Clearance ReductionsStove Heat Shields Wall ShieldsMeasured from the top and sides of the stove Fireplace and Mantel Trim ShieldsConstruction Requirements Alcove InstallationsIntrepid Multi-Fuel Clearance Chart Intrepid Multi-fuel Clearance Diagrams Wall Shield Requirements for Common Installations Parallel Installations Assembly Intrepid Multi-fuel’s Controls OperationPrimary Air Control Glass Door Panels DamperFront Grate Two Ways to Add FuelDamper must be open when starting a fire or when refueling Use the Air Control Settings that Work Best for YouAdd larger pieces of wood as the fire begins to burn well Refuel While the Embers Are Still HotDraft Management Ash DisposalSteel Chimney Indoor/Outdoor locationSingle Venting Pipe & Chimney LayoutCreosote FuelNegative Pressure Draft TestingConclusion Maintenance Damper Adjustment How to Adjust the Door LatchTighten the Damper Handle as Needed Replace the Stove Gaskets as NeededPermanent Gaskets Adjust the Door if NecessaryChimney System Annual MaintenanceIntrepid Multi-Fuel Heater Intrepid Multi-Fuel Heater Intrepid Multi-Fuel Heater Warranty

1695 specifications

The Vermont Castings 1695 is a stellar model in the realm of wood stoves, noted for its blend of traditional craftsmanship and modern efficiency. This timeless piece not only serves as a functional heating solution but also as a stylish addition to home décor, making it a popular choice for homeowners seeking both utility and aesthetics.

One of the standout features of the Vermont Castings 1695 is its impressive heating capacity. With the ability to heat areas up to 2,000 square feet, this stove is ideal for larger living spaces or for providing supplementary heat in smaller homes. Its robust construction, crafted from heavy-duty cast iron, ensures that heat is evenly distributed throughout the room, creating a cozy atmosphere.

The 1695’s primary innovation lies in its advanced combustion technology. With a patented secondary combustion process, this wood stove maximizes efficiency by re-burning gases and particulates that would typically escape through the flue. This not only results in cleaner emissions, which is beneficial for the environment, but also means longer burn times and less frequent reloading of wood, allowing users to enjoy their fire without constant maintenance.

Moreover, the Vermont Castings 1695 features a smooth-operating air control system. This system enables users to easily adjust the burn rate, which helps to manage heat output and fuel consumption. This level of control ensures that the stove operates at peak efficiency, reducing waste and optimizing performance.

In terms of design, the Vermont Castings 1695 boasts an elegant look with a classic cast-iron façade and an attractive firebox window. The large viewing window allows users to enjoy the mesmerizing flames while providing a source of warmth. The design is not just visually appealing; the cast iron surface also retains heat well, radiating warmth long after the fire has died down.

Durability is another hallmark of the Vermont Castings brand, and the 1695 model is no exception. Built to last, it withstands the rigors of regular use, making it a wise investment for homeowners. Additionally, the stove is available in various finishes, allowing for customization to fit different home styles.

In summary, the Vermont Castings 1695 is a well-rounded wood stove that combines traditional aesthetics with modern technologies. Its efficiency, effective heating capability, and attractive design make it a favored choice among wood stove enthusiasts and environmentally conscious consumers alike. Whether used as a primary heating source or a supplemental one, this stove delivers warmth, comfort, and style.