Securing the Single-wall Connector to a Masonry Chimney

Both freestanding masonry chimneys and fireplace masonry chimneys may be used for your installation.

Freestanding Installations

If the chimney connector must pass through a combus- tible wall to reach the chimney, follow the recommen- dations in the Wall Pass-Through section that follows. The opening through the chimney wall to the flue

(the “breach”) must be lined with either a ceramic or metal cylinder, called the “thimble”, which is cemented securely in place. Most chimney breaches incorporate thimbles, but the fit must be snug and the joint between the thimble and the chimney wall must be cemented firmly.

A special piece called the “thimble sleeve,” slightly smaller in diameter than standard connectors and most thimbles, will ease the removal of the chimney connec- tor system for inspection and cleaning. (Fig. 6) Thimble sleeves should be available from your local dealer.

To install a thimble sleeve, slide it into the breach until it is flush with the inner flue wall. Don’t extend it into the actual flue passage, as this could interfere with the draft.

The thimble sleeve should protrude 1-2" (25-50

mm)into the room. Use furnace cement and thin gasketing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws.

Thimble

Sleeve

Flue

Chimney

Connector

Keep sleeve end flush with flue tile

ST243

Fig. 6 The thimble, made of either ceramic or metal, must be cemented securely in place.

Without a thimble, a suitable length of chimney connector can be extended through the breach to the inner face of the flue liner, and cemented securely in place. Additional pieces of connector are then attached with sheet metal screws.

Fireplace Installations

The chimney connector may be connected to the chimney above the fireplace opening.

Above the Fireplace

The Defiant may be connected to a chimney above a fireplace opening. In such installations, the stove stands on the hearth in front of the fireplace and the chimney connector rises from the stove top and then angles ninety degrees back into the chimney. The chimney liner should extend to the point at which the chimney connector enters the chimney. (Fig. 7)

Check These

Clearances *

*

 

Mantel

D E F I A N T

Seal

 

This Off

ST244a

Fig. 7 In this installation, the chimney connector attaches to the chimney above the fireplace opening.

8

Image 8
Contents Defiant Welcome Save These Instructions for Future ReferenceTable of Contents Story of the DefiantSpecifications Defiant, ModelChimney Height InstallationOutside Air What Kind of Chimney to Use Masonry ChimneysPrefabricated Chimneys Chimney SizeChimney Connector Guidelines Single-wall Chimney ConnectorsSecuring the Single-wall Connector to a Masonry Chimney Freestanding InstallationsFireplace Installations Above the FireplaceThrough the Fireplace Wall pass-ThroughsFloor Protection for Fireplace Installation Floor ProtectionWall Shields Keep the Stove a Safe Distance from Surrounding MaterialsSafe Ways to Reduce Clearances Defiant Clearance Chart Stove Clearance Unprotected Surfaces Protected SurfacesDefiant Clearance Diagrams Unprotected Surfaces Protected SurfacesRear heat shield installed on the Defiant Stove Stove Heat ShieldsDistance from the Center of the Flue Collar to the Wall Defiant With Rear Heat Shield onlyAssembly Operation Defiant ControlsAssemble the Removable Insert Handle Single Air Control Regulates Heat Output and Burn TimeTwo Ways to Add Fuel Damper Directs Air Flow Within the StoveInfra-Red Reflective Glass Panels For Clear Fire Viewing Andirons Help Protect the GlassBurn Only High-Quality Wood Surface Thermometer is a Valuable Guide to OperationHigh-Efficiency Wood Burning With Catalytic Combustion Use the Air Control Settings that Work Best for YouDefiant Control Settings Conditioning Your Stove Starting and Maintaining a Wood FireRefuel While the Embers Are Still Hot Add larger pieces of wood as the fire begins to burnAsh Disposal Masonry Chimney Steel ChimneyIndoor/Outdoor Location Flue SizingDraft Testing Single VentingCreosote FuelNegative Pressure ConclusionMaintenance Keep Your Stove Looking New Working Its BestAdjust the Damper as Needed How to Adjust the Door LatchesCheck the Operation Primary Air Shutter Tighten the Damper Handle as NeededInspection and Cleaning When To Suspect a Combustor ProblemRemoving and Cleaning the Combustor Catalytic ElementRemove the bricks and the brick retainer Replace the Stove Gaskets as Needed Annual Maintenance Adjust the Door Latch If NecessaryChimney System Permanent Defiant GasketsBlockage Masking and PoisoningFlame Impingement OverfiringAppendix Chimney and Fireplace Hazards For a fireplaceDefiant Woodburning Stove Defiant Warranty Vermont Castings Majestic Products Company