OPERATING SEQUENCE
The booster heater is designed to produce
| PowerMax200tm Performance Data |
|
Temperature rise | Gallons per Minute | Gallons per Hour |
40o F | 8.7 | 520 |
50o F | 7.0 | 420 |
60o F | 5.8 | 348 |
70o F | 5.0 | 300 |
140o F | 2.5 (7.5 for 15 sec. Per minute) 150 |
After the necessary power, water, gas and vent connections are completed correctly and all air is purged from gas and water piping, the unit is started by turning on the power switch located on the top, front of the left side panel. The combustion air fan will start and run continuously and the digital temperature display will light, showing the water temperature in the accumulator tank. If the tank temperature sensor detects water temperature below the set point, it will turn on the internal circulating pump, prove water flow, combustion air flow and
The internal circulating pump will operate whenever the thermostat is calling for heat. The combustion air blower operates continuously whenever the
The operating temperature control is