Vanguard Heating PM400, PM200 operation manual Exhaust Venting

Page 5

COMBUSTION AIR / VENTILATION

The POWERMAXtm must be provided with an adequate supply of air for proper combustion and ventilation as required by the National Fuel Gas Code, ANSI Z 223.1 or any local codes that supercede the National Code. Do not obstruct the combustion and/or ventilation air supply openings.

CAUTION: Combustion air must not be contaminated by corrosive vapors or fumes, i.e. salt, chlorine, refrigerant gases, detergents, paints, cleaners, etc.. Any damage caused by insufficient or contaminated combustion air or improper venting will not be covered under the warranty.

EXHAUST VENTING

The POWERMAXtm Booster Heater is classified as a category IV appliance (positive flue pressure, flue gas temperature of approximately 190 degrees Fahrenheit, possible condensate). Vent piping must be one of the types detailed in this manual or a factory approved (in writing) alternate and must be installed according to the vent pipe manufacturers instructions. All joints must be properly sealed and secured to maintain joint integrity. All vent piping must slope toward the appliance a minimum of 1/4 inch per foot of length. The National Fuel Gas Code, ANSI Z223.1 requires that the booster heater be vented in one of the following three ways:

1.Into the dishwasher exhaust system. (See fig.1). The vent pipe must not penetrate any grease filter, but should terminate within the hood “capture zone”. In cases of a “pantleg” type of vent (see fig. 2), the vent pipe may terminate below an approved ‘eyebrow’ penetration of the duct. When vented into the dishwasher exhaust system, an electrical interlock must be provided (by others) to prevent the appliance from firing if the exhaust system is not providing sufficient draft for any reason.

3

Image 5
Contents Do not Discard this Manual Important for Your SafetyGAS INFRA-RED Water Booster Heaters What to do if YOU Smell GASTable of Contents General Information Unpacking Installation CodesInstallation Clearances Exhaust Venting Page GAS Piping Examples of Acceptable Vent PIPING/ See Appendix aWater Requirements Water Piping Page Electrical Page Page Operating Sequence Check Electric Controls Fill the Booster HeaterOperating Instructions For Your SAFETY, Read Before OperatingTo Turn OFF GAS to Appliance Maintenance Problem Cause Remedy Trouble ShootingPART# Description Replacement Parts ListVanguard TECHNOLOGY, INC Limited WarrantyAppendix a Typical Special Stainless Steel Venting See illustration #1 below Clearance to CombustiblesSide Wall Venting Installation Side Wall Venting InstallationVertical Venting Factory Authorized PowerMax Start-Up Verification Worksheet Vanguard Technology Inc

PM200, PM400 specifications

The Vanguard Heating PM200 and PM400 models represent a significant advancement in the world of heating solutions, designed specifically to provide efficient and effective warmth to various spaces. These heating units are renowned for their performance, reliability, and innovative features, making them ideal for both residential and commercial applications.

The PM200 is a compact yet powerful heating solution that delivers an impressive 200,000 BTU output. This model is particularly favored for smaller spaces or areas where precise heating is required. One of its standout features is its user-friendly digital thermostat, allowing for easy temperature adjustments and precise control over heating schedules. This digital interface enhances user experience, providing necessary information at a glance and facilitating efficient energy usage.

On the other hand, the PM400 offers an even more robust heating capacity, with an output of 400,000 BTU. This model is designed for larger spaces or commercial environments that demand higher heating output. Both units come equipped with advanced technology that allows them to operate efficiently while minimizing energy consumption. The high-efficiency heat exchangers used in both models are engineered to maximize heat transfer, ensuring that energy is used judiciously.

Vanguard Heating has also incorporated safety features into the PM200 and PM400 to enhance user protection. Each unit comes with an integrated overheat protection system, ensuring that operations are safe even during extended usage. Additionally, the units are designed with durable materials that contribute to their longevity, minimizing the need for frequent replacements or repairs.

Both models are versatile, allowing for various installation methods, including wall-mounted or freestanding configurations. This adaptability ensures that they can fit seamlessly into any space without disrupting the overall aesthetic.

Moreover, the PM200 and PM400 units are engineered for quiet operation, which is a crucial feature for both residential and commercial settings. Their design ensures that they do not become a source of distraction, allowing users to enjoy a comfortable environment without the accompanying noise often associated with traditional heating systems.

In summary, Vanguard Heating PM200 and PM400 models are excellent choices for those seeking reliable, efficient, and user-friendly heating solutions. With their range of features and technologies, they continue to set the standard in the heating industry, ensuring users enjoy optimal comfort in any setting.