INSTALLATION CODES

Installation must be performed in accordance with state and local codes, or, in the absence of local codes, with the following: National Fuel Code, ANSI Z223.1 (latest edition) the National Electric Code (NEC) ANSI/NFPA 70 (latest edition). Canada: CAN/CGA B149.1, CAN/CGA B149.2 and CSA C22.2 No. 1 (latest edition).

UNPACKING

Immediately after unpacking, check thoroughly for any possible shipping damage. If the POWERMAXtm is found to be damaged, contact the carrier immediately (15 days maximum). Be sure to save all the packaging materials for shipper’s inspection.

LOCATING THE POWERMAXtm BOOSTER HEATER

Locate the POWERMAXtm so that all required clearances are maintained. The appliance must be located in an area that is clear and free from combustible materials, including gasoline and other flammable or corrosive liquids and vapors. The booster heater should not be located in an area where water leakage could cause damage to adjacent areas or areas below the unit. If this is not possible, the booster heater should be installed in an adequate catch pan (preferably stainless steel) that is properly drained. If appliance is installed on carpeting, it must be installed on a wood or metal panel extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in each direction. The booster heater should be installed with no more than five feet of pipe between the 180- degree outlet and the dishwasher rinse valve (as specified by NSF-5). If the piping exceeds five feet, the optional circulation return kit must be installed to maintain proper temperature at the dishwasher rinse valve. The POWERMAXtm may be installed up to 150 feet from the dishwasher when using the circulation kit. Call factory for details.

INSTALLATION CLEARANCES

Minimum clearances from combustible or non-combustible construction -

8” (fire 2”, service 8”) Left side, 2” Right side, 6” Back, 0” Top, 24” Front (minimum for service). The four 6” adjustable legs allow the unit to be leveled on uneven floors by screwing the feet up or down as needed.

2

Image 4
Contents Important for Your Safety Do not Discard this ManualGAS INFRA-RED Water Booster Heaters What to do if YOU Smell GASTable of Contents General Information Installation Clearances Installation CodesUnpacking Exhaust Venting Page Examples of Acceptable Vent PIPING/ See Appendix a GAS PipingWater Requirements Water Piping Page Electrical Page Page Operating Sequence Fill the Booster Heater Check Electric ControlsFor Your SAFETY, Read Before Operating Operating InstructionsTo Turn OFF GAS to Appliance Maintenance Trouble Shooting Problem Cause RemedyReplacement Parts List PART# DescriptionLimited Warranty Vanguard TECHNOLOGY, INCAppendix a Typical Special Stainless Steel Venting Clearance to Combustibles See illustration #1 belowSide Wall Venting Installation Side Wall Venting InstallationVertical Venting Factory Authorized PowerMax Start-Up Verification Worksheet Vanguard Technology Inc

PM200, PM400 specifications

The Vanguard Heating PM200 and PM400 models represent a significant advancement in the world of heating solutions, designed specifically to provide efficient and effective warmth to various spaces. These heating units are renowned for their performance, reliability, and innovative features, making them ideal for both residential and commercial applications.

The PM200 is a compact yet powerful heating solution that delivers an impressive 200,000 BTU output. This model is particularly favored for smaller spaces or areas where precise heating is required. One of its standout features is its user-friendly digital thermostat, allowing for easy temperature adjustments and precise control over heating schedules. This digital interface enhances user experience, providing necessary information at a glance and facilitating efficient energy usage.

On the other hand, the PM400 offers an even more robust heating capacity, with an output of 400,000 BTU. This model is designed for larger spaces or commercial environments that demand higher heating output. Both units come equipped with advanced technology that allows them to operate efficiently while minimizing energy consumption. The high-efficiency heat exchangers used in both models are engineered to maximize heat transfer, ensuring that energy is used judiciously.

Vanguard Heating has also incorporated safety features into the PM200 and PM400 to enhance user protection. Each unit comes with an integrated overheat protection system, ensuring that operations are safe even during extended usage. Additionally, the units are designed with durable materials that contribute to their longevity, minimizing the need for frequent replacements or repairs.

Both models are versatile, allowing for various installation methods, including wall-mounted or freestanding configurations. This adaptability ensures that they can fit seamlessly into any space without disrupting the overall aesthetic.

Moreover, the PM200 and PM400 units are engineered for quiet operation, which is a crucial feature for both residential and commercial settings. Their design ensures that they do not become a source of distraction, allowing users to enjoy a comfortable environment without the accompanying noise often associated with traditional heating systems.

In summary, Vanguard Heating PM200 and PM400 models are excellent choices for those seeking reliable, efficient, and user-friendly heating solutions. With their range of features and technologies, they continue to set the standard in the heating industry, ensuring users enjoy optimal comfort in any setting.