Vanguard Heating PM200, PM400 Factory Authorized PowerMax Start-Up Verification Worksheet

Page 26

2 9 4 9 5 A irp o rt R o a d , E u g e n e , O R 9 7 4 0 2 T e l:(5 4 1 ) 4 6 1 - 6 0 2 0 F a x :(5 4 1 ) 4 6 1 - 6 0 2 3 T o ll F re e : 1 - 8 0 0 - 6 2 4 - 4 8 0 9

Factory Authorized PowerMax Start-Up

Verification Worksheet

Job Name:______________________________________________________________

Job Location:____________________________________________________________

Dealer Name:___________ Serial # ___________________

! Verify incoming water temperature to booster heater is 110Ε to 140Ε. ! Verify size of vent piping. ____” dia.

! Is there any horizontal vent piping? YES / NO (Circle one) How much? _____ ft.

! Is vent pipe correct pipe for application? ‘Z’-vent Mfg. By Z-Flex U.S., Saf-T-Vent Mfg. By Heat Fab., Inc., or StaR-34 By Flex-L International. All are constructed of AL29- 4Ctm Stainless Steel.

! If an auxiliary power vent is being used, is it installed with an indirect connection, per drawing?

Exhaust

!If used, is power vent installed and operating correctly? YES / NO (Circle One)

!Must come on with burner and continue for 4 minutes after burner shutdown.

!Verify electrical connection to unit is correct and to NEC code.

!Verify size, volume, pressure and type of gas supply & that they are in accordance with manufacturers specification: 3.25"w.c. NG or 8"w.c. LP; Check at test port on gas

!

!

!

!

!

!

!

valve.

Verify gas supply pipe size. _____” dia.

Verify pipe size, flow pressure and volume of water supply to unit according to manufacturers specifications. Water supply pipe size. _____” dia.

Does dishwasher have pressure-regulating valve and gauge? Flow rinse pressure must be 18-20 p.s.i. YES / NO (Circle one)

Verify that pipe length from booster accumulator outlet or circulating loop to rinse valve does not exceed 5 feet. (NSF maximum) and is correct diameter (both supply and return)

_____” dia.

Verify that unit has been flushed properly; both water & gas piping. Check all gas connections for leaks.

Check all water connections for leaks.

24

Image 26
Contents GAS INFRA-RED Water Booster Heaters Important for Your SafetyDo not Discard this Manual What to do if YOU Smell GASTable of Contents General Information Unpacking Installation CodesInstallation Clearances Exhaust Venting Page Examples of Acceptable Vent PIPING/ See Appendix a GAS PipingWater Requirements Water Piping Page Electrical Page Page Operating Sequence Fill the Booster Heater Check Electric ControlsFor Your SAFETY, Read Before Operating Operating InstructionsTo Turn OFF GAS to Appliance Maintenance Trouble Shooting Problem Cause RemedyReplacement Parts List PART# DescriptionLimited Warranty Vanguard TECHNOLOGY, INCAppendix a Typical Special Stainless Steel Venting Clearance to Combustibles See illustration #1 belowSide Wall Venting Installation Side Wall Venting InstallationVertical Venting Factory Authorized PowerMax Start-Up Verification Worksheet Vanguard Technology Inc

PM200, PM400 specifications

The Vanguard Heating PM200 and PM400 models represent a significant advancement in the world of heating solutions, designed specifically to provide efficient and effective warmth to various spaces. These heating units are renowned for their performance, reliability, and innovative features, making them ideal for both residential and commercial applications.

The PM200 is a compact yet powerful heating solution that delivers an impressive 200,000 BTU output. This model is particularly favored for smaller spaces or areas where precise heating is required. One of its standout features is its user-friendly digital thermostat, allowing for easy temperature adjustments and precise control over heating schedules. This digital interface enhances user experience, providing necessary information at a glance and facilitating efficient energy usage.

On the other hand, the PM400 offers an even more robust heating capacity, with an output of 400,000 BTU. This model is designed for larger spaces or commercial environments that demand higher heating output. Both units come equipped with advanced technology that allows them to operate efficiently while minimizing energy consumption. The high-efficiency heat exchangers used in both models are engineered to maximize heat transfer, ensuring that energy is used judiciously.

Vanguard Heating has also incorporated safety features into the PM200 and PM400 to enhance user protection. Each unit comes with an integrated overheat protection system, ensuring that operations are safe even during extended usage. Additionally, the units are designed with durable materials that contribute to their longevity, minimizing the need for frequent replacements or repairs.

Both models are versatile, allowing for various installation methods, including wall-mounted or freestanding configurations. This adaptability ensures that they can fit seamlessly into any space without disrupting the overall aesthetic.

Moreover, the PM200 and PM400 units are engineered for quiet operation, which is a crucial feature for both residential and commercial settings. Their design ensures that they do not become a source of distraction, allowing users to enjoy a comfortable environment without the accompanying noise often associated with traditional heating systems.

In summary, Vanguard Heating PM200 and PM400 models are excellent choices for those seeking reliable, efficient, and user-friendly heating solutions. With their range of features and technologies, they continue to set the standard in the heating industry, ensuring users enjoy optimal comfort in any setting.