13 Operating Instructions

A. Before Lighting Appliance

Before lighting this appliance determine if it has a Standing Pilot or Intellifire ignition system by opening the control access panel to view wiring system and gas valve. If this appliance has a red or black ignitor button (see Figure 10.1) this appliance has a Standing Pilot ignition system. If there is no red or black ignitor button, this appliance has an Intellifire ignition system.

CAUTION

If installing Intellifire ignition battery backup:

Do not install batteries if the backup mode may not be used for extended time.

Batteries may leak.

Install batteries only when needed for power outage.

Before operating this appliance have a qualified tech- nician:

Remove all shipping materials from inside and/or under- neath the firebox.

Review proper placement of logs, rockwool, lava rock, and vermiculite.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper posi- tion.

Ensure that the flow of combustion and ventilation air is not obstructed (front grilles and vent caps).

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

• Do not touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING

Glass door must be in place when appliance is operating.

Risk of:

Combustion Fumes

Fire

Do NOT operate appliance with glass door removed.

• Open viewing glass for servicing only.

Glass door MUST be in place and sealed before operating appliance.

Only use glass door certified for use with appliance.

Glass replacement should be done by qualified technician.

WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

47

Image 47
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Selecting Appliance Location Framing and ClearancesClearance to Combustibles Constructing the Appliance ChaseClearances To Ceiling Mantel ProjectionsSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsV1 Minimum H1 + H2 Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow Minimum MaximumMin Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsE a K R E Flue Restrictor InstructionsMaximum + V 2 Min H1+ H2 V1 + V2 Minimum H1+ H2 Maximum Top Vent Vertical TerminationH1 = 16 in mm Maximum Rear Vent Horizontal TerminationH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max H1 Maximum V1 Minimum H1+ H2 MaximumH1+ H2 Maximum V1 Minimum Rear Vent Vertical TerminationV1 Minimum H1+ H2+ H3 Maximum 10 ft Maximum Minimum + H 2 MaximumCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP SLP Vertical Penetration FramingVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Proceed to . C Appliance PreparationTop Vent Securing and Leveling the Appliance Installing the Non-combustible BoardInstall the Optional HEAT-ZONE-GAS Kit Assemble Pipe Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Vent Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Refer to of this manual Install Horizontal Termination Cap DVP and SLP PipeAnsi Z223.1 and CAN/CGA-B149 installation codes Pressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Optional Accessories Requirements Recommendation for WireIntellifire Ignition System Wiring Connecting to the ApplianceIntellifire Pilot Ignition IPI Wiring Diagram Standing Pilot Ignition System WiringVAC to wall switch Junction Box InstallationWall Switch Installation for Fan Optional Facing Material FinishingFinish Door FIT Material See Maximum Thickness Finishing MaterialEmber Placement Appliance SetupClean the Appliance AccessoriesLog #1 SRV2103-107 Positioning the Logs12 Front View Grilles and Trim Glass AssemblyAir Shutter Setting Screen MeshBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceLighting Instructions IPI Standing Pilot Ignition For Your Safety Read Before Lighting Lighting InstructionsAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksLocation Inches Millimeters Appliance Dimension DiagramReference Materials P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components Horizontal Termination Cap13-3/4 13-7/8 352 mm 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm 302 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Roof Flashing Ceiling Firestop Support ElbowWall Shield Firestop RF4-8Adapter SnorkelSupport Box-Black PVK-80Part number list on following Log Set AssemblyService Parts IPI Ignition Service Parts List 6000G, 6000G-IPIAt Depot Standing PilotStocked Standing Pilot Valve Assembly6000G-IPI IPI Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

6000G-IPILP, 6000G-IPI, 6000G, 6000G-LP specifications

The Heat & Glo LifeStyle 6000 series offers a sophisticated solution for homeowners seeking both performance and style in their heating options. With models such as the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, this series combines innovative technologies with elegant design, making it a preferred choice for many.

One of the standout features of the LifeStyle 6000 series is its advanced heating technology. The units utilize Direct Vent technology, which ensures efficient combustion by drawing air from the outside for combustion and venting exhaust air outdoors. This not only enhances efficiency but also maintains a safe and comfortable indoor environment. Additionally, these models are designed with advanced burner systems that provide realistic flame effects and a warm ambiance, making them perfect for any living space.

The aesthetic appeal of the LifeStyle 6000 series cannot be overlooked. These fireplaces boast a contemporary design that seamlessly integrates into various architectural styles. With customizable options like different front styles and finishes, homeowners can truly make the fireplace their own. The impressive viewing area, thanks to large glass doors, amplifies the beauty of the flames while also allowing for maximum heat output.

Thermal efficiency is a key characteristic of the LifeStyle 6000 series. With an impressive heating capacity, these units can effectively warm large spaces. Furthermore, they feature a range of BTU outputs, allowing users to select the model that best suits their heating needs. Models equipped with the IntelliFire Ignition system further enhance usability, providing reliable startup with the convenience of remote control operation.

Safety is also paramount in the design of the LifeStyle 6000 series. Each model comes with built-in safety features such as a glass safety barrier and optional automatic shut-off systems, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle 6000 series, including the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, stands out in the market for its combination of modern aesthetics, innovative heating technologies, and robust safety features. Whether enhancing a cozy living room or providing warmth in a spacious area, these fireplaces offer a stylish and efficient heating solution for contemporary homes.