Heat & Glo LifeStyle 6000G-LP Service Parts List 6000G, 6000G-IPI, At Depot, Standing Pilot

Page 66

C. Service Parts List

 

6000G, 6000G-IPI

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

 

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

DESCRIPTION

 

COMMENTS

PART NUMBER

 

 

Log Assembly

 

 

LOGS-6000G

Y

1

Log #1

 

 

SRV2103-107

 

2

Log #2

 

 

SRV2103-108

 

3

Log #3

 

 

SRV2103-110

 

4

Log #4

 

 

SRV2103-109

 

5

Log #5

 

 

SRV2103-111

 

6

Grate Assembly

 

 

2103-005

 

7

Burner Assembly

 

 

SRV2103-007

Y

8

Non-Combustible Board

 

 

2101-312

 

9

Glass Assembly

 

 

GLA-6000G

Y

10

Surround

 

 

2101-260

 

11

Junction box

 

 

4021-013

Y

 

 

 

 

 

 

 

Flue Restrictor

 

 

385-128

 

 

Gasket Assembly

 

 

 

 

 

Includes Vent, Seal Cap, Burner Neck, Shutter

 

 

2103-081

 

 

Bracket, Manifold and Valve Plate gaskets

 

 

 

 

 

Glass Latch Assembly

 

 

386-122A

Y

 

Mineral Wool

 

 

050-721

 

 

Vermiculite Embers

 

 

Mystic-Embers

 

 

Touch Up Paint

 

 

203-9

 

 

 

 

 

 

 

 

Standing Pilot

 

 

 

 

Conversion Kit, NG

 

 

NGK-6G

Y

 

Conversion Kit, LP

 

 

LPK-6G

Y

 

Pilot Orifice, NG

 

 

2103-116

Y

 

Pilot Orifice, LP

 

 

2103-117

Y

 

Regulator, NG

 

 

230-1570

Y

 

Regulator, LP

 

 

230-1520

Y

 

Thermocouple

 

 

446-511

Y

 

Pilot Tube

 

 

SRV485-301

Y

 

Thermopile

 

 

2103-512

Y

 

IPI Ignition

 

 

 

 

Conversion Kit, NG

 

 

NGK-6G-IPI

Y

 

Conversion Kit, LP

 

 

LPK-6G-IPI

Y

 

Pilot Orifice, NG

 

 

593-528

Y

 

Pilot Orifice, LP

 

 

593-527

Y

 

Regulator, NG

 

 

NGK-DXV

Y

 

Regulator, LP

 

 

LPK-DXV

Y

Additional service part numbers on following page.

66

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

Image 66
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesClearance to Combustibles Mantel Projections To CeilingTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsMinimum Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows Min Max V2 Min H2 MaxFlue Restrictor Instructions E a K R EMaximum + V 2 Min Top Vent Vertical Termination H1+ H2 V1 + V2 Minimum H1+ H2 MaximumRear Vent Horizontal Termination H1 = 16 in mm MaximumH1 Maximum V1 Minimum H1+ H2 Maximum H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 MaxRear Vent Vertical Termination H1+ H2 Maximum V1 MinimumMaximum Minimum + H 2 Maximum V1 Minimum H1+ H2+ H3 Maximum 10 ftWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationVertical Penetration Framing Pipe DVP SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Installing the Non-combustible Board Securing and Leveling the ApplianceInstall the Optional HEAT-ZONE-GAS Kit Assemble Vent Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Pipe Sections DVP Pipe OnlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Gas Pressures Gas InformationFuel Conversions Gas Connection Pressure Natural Gas PropaneHigh Altitude Installations Connecting to the Appliance Recommendation for WireIntellifire Ignition System Wiring Optional Accessories RequirementsStanding Pilot Ignition System Wiring Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalVAC to wall switch Finishing Facing MaterialFinishing Material Finish Door FIT Material See Maximum ThicknessAccessories Appliance SetupClean the Appliance Ember PlacementPositioning the Logs Log #1 SRV2103-10712 Front View Screen Mesh Glass AssemblyAir Shutter Setting Grilles and TrimOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance Lighting Instructions IPIFinal inspection by For Your Safety Read Before Lighting Lighting Instructions Standing Pilot IgnitionFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Vent Components Diagrams P 4 5 4 5 E lb o wHorizontal Termination Cap DVP vent components302 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm 13-3/4 13-7/8 352 mm 349 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP RF4-8 ElbowWall Shield Firestop Roof Flashing Ceiling Firestop SupportPVK-80 SnorkelSupport Box-Black AdapterLog Set Assembly Service PartsPart number list on following Standing Pilot Service Parts List 6000G, 6000G-IPIAt Depot IPI IgnitionStanding Pilot Valve Assembly StockedIPI Valve Assembly 6000G-IPICONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

6000G-IPILP, 6000G-IPI, 6000G, 6000G-LP specifications

The Heat & Glo LifeStyle 6000 series offers a sophisticated solution for homeowners seeking both performance and style in their heating options. With models such as the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, this series combines innovative technologies with elegant design, making it a preferred choice for many.

One of the standout features of the LifeStyle 6000 series is its advanced heating technology. The units utilize Direct Vent technology, which ensures efficient combustion by drawing air from the outside for combustion and venting exhaust air outdoors. This not only enhances efficiency but also maintains a safe and comfortable indoor environment. Additionally, these models are designed with advanced burner systems that provide realistic flame effects and a warm ambiance, making them perfect for any living space.

The aesthetic appeal of the LifeStyle 6000 series cannot be overlooked. These fireplaces boast a contemporary design that seamlessly integrates into various architectural styles. With customizable options like different front styles and finishes, homeowners can truly make the fireplace their own. The impressive viewing area, thanks to large glass doors, amplifies the beauty of the flames while also allowing for maximum heat output.

Thermal efficiency is a key characteristic of the LifeStyle 6000 series. With an impressive heating capacity, these units can effectively warm large spaces. Furthermore, they feature a range of BTU outputs, allowing users to select the model that best suits their heating needs. Models equipped with the IntelliFire Ignition system further enhance usability, providing reliable startup with the convenience of remote control operation.

Safety is also paramount in the design of the LifeStyle 6000 series. Each model comes with built-in safety features such as a glass safety barrier and optional automatic shut-off systems, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle 6000 series, including the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, stands out in the market for its combination of modern aesthetics, innovative heating technologies, and robust safety features. Whether enhancing a cozy living room or providing warmth in a spacious area, these fireplaces offer a stylish and efficient heating solution for contemporary homes.