Heat & Glo LifeStyle 6000G-IPILP, 6000G-LP owner manual Intellifire Ignition System

Page 53

B. Intellifire Ignition System

Symptom

Possible Cause

Corrective Action

 

 

 

1. The ignitor/module

a. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor

makes noise, but no

 

are connected to correct terminals on module and pilot assembly.

spark.

 

Reversed wires at the module may cause system to make sparking

 

 

noise, but spark may not be present at pilot hood.

 

 

 

 

b. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from mod-

 

shorts in the wiring.

ule to pilot assembly. Rod closest to pilot hood should be ignitor.

 

 

Verify connections underneath pilot assembly are tight; also verify

 

 

connections are not grounding out to metal chassis, pilot burner,

 

 

pilot enclosure, mesh screen if present, or any other metal object.

 

 

 

 

c. Ignitor gap is too large.

Verify gap of igniter to pilot hood. The gap should be approximately

 

 

.17 inch or 1/8 inch.

 

 

 

 

d. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF Rocker switch or wall

 

 

switch in ON position. Hold ground wire about 3/16 inch away from

 

 

“I” terminal on module. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

2. Pilot won’t light,

a. Transformer installed correctly.

Verify that transformer is installed and plugged into module. Check

there is no noise or

 

voltage of transformer under load at spade connection on module

spark.

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

b. A shorted or loose connection in wir-

Remove and reinstall the wiring harness that plugs into module.

 

ing configuration or wiring harness.

Verify there is a tight fit. Verify pilot assembly wiring to module.

 

 

Remove and verify continuity of each wire in wiring harness.

 

 

 

 

c. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

d. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

 

 

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF Rocker switch or wall

 

 

switch in ON position. Hold ground wire about 3/16 inch away from

 

 

“I” terminal on module. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

3. Pilot lights but con-

a. A shorted or loose connection in

Verify all connections to wiring diagram in manual. Verify connec-

tinues to spark, and

sensor rod.

tions underneath pilot assembly are tight. Verify connections are

main burner will not ig-

 

not grounding out to metal chassis, pilot burner, pilot enclosure or

nite. (If the pilot contin-

 

screen if present, or any other metal object.

ues to spark after the

 

 

b. Poor flame rectification or contami-

Verify that flame is engulfing sensor rod. If the pilot assembly does

pilot flame has been lit,

flame rectification has

nated sensor rod.

not have a ground strap, consider installing one to increase flame

 

rectification. Verify correct pilot orifice is installed and inlet gas

not occurred.)

 

 

specifications. Flame carries rectification current, not the gas. If

 

 

 

 

flame lifts from pilot hood, the circuit is broken. A wrong orifice or

 

 

too high an inlet pressure can cause pilot flame to lift. The sensor

 

 

rod may be contaminated. Clean sensor rod with emery cloth.

 

 

 

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

53

Image 53
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Installation to ensure maximum safety and benefitGetting Started Selecting Appliance Location Framing and ClearancesClearance to Combustibles Constructing the Appliance ChaseClearances To Ceiling Mantel ProjectionsSee .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsMinimum Maximum V1 Minimum H1 + H2 MaximumMin Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsE a K R E Flue Restrictor InstructionsMaximum + V 2 Min H1+ H2 V1 + V2 Minimum H1+ H2 Maximum Top Vent Vertical TerminationH1 = 16 in mm Maximum Rear Vent Horizontal TerminationH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max H1 Maximum V1 Minimum H1+ H2 MaximumH1+ H2 Maximum V1 Minimum Rear Vent Vertical TerminationV1 Minimum H1+ H2+ H3 Maximum 10 ft Maximum Minimum + H 2 MaximumPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Vertical Penetration FramingVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Proceed to . C Appliance PreparationTop Vent Securing and Leveling the Appliance Installing the Non-combustible BoardInstall the Optional HEAT-ZONE-GAS Kit Attach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Refer to of this manual Install Horizontal Termination Cap DVP and SLP PipeAnsi Z223.1 and CAN/CGA-B149 installation codes Fuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Standing Pilot Ignition System WiringVAC to wall switch Junction Box InstallationWall Switch Installation for Fan Optional Facing Material FinishingFinish Door FIT Material See Maximum Thickness Finishing MaterialClean the Appliance Appliance SetupAccessories Ember PlacementLog #1 SRV2103-107 Positioning the Logs12 Front View Air Shutter Setting Glass AssemblyScreen Mesh Grilles and TrimBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceLighting Instructions IPI Standing Pilot Ignition For Your Safety Read Before Lighting Lighting InstructionsAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksLocation Inches Millimeters Appliance Dimension DiagramReference Materials P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components Horizontal Termination CapRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2302 mm 13-3/4 13-7/8 352 mm 349 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Wall Shield Firestop ElbowRF4-8 Roof Flashing Ceiling Firestop SupportSupport Box-Black SnorkelPVK-80 AdapterPart number list on following Log Set AssemblyService Parts At Depot Service Parts List 6000G, 6000G-IPIStanding Pilot IPI IgnitionStocked Standing Pilot Valve Assembly6000G-IPI IPI Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

6000G-IPILP, 6000G-IPI, 6000G, 6000G-LP specifications

The Heat & Glo LifeStyle 6000 series offers a sophisticated solution for homeowners seeking both performance and style in their heating options. With models such as the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, this series combines innovative technologies with elegant design, making it a preferred choice for many.

One of the standout features of the LifeStyle 6000 series is its advanced heating technology. The units utilize Direct Vent technology, which ensures efficient combustion by drawing air from the outside for combustion and venting exhaust air outdoors. This not only enhances efficiency but also maintains a safe and comfortable indoor environment. Additionally, these models are designed with advanced burner systems that provide realistic flame effects and a warm ambiance, making them perfect for any living space.

The aesthetic appeal of the LifeStyle 6000 series cannot be overlooked. These fireplaces boast a contemporary design that seamlessly integrates into various architectural styles. With customizable options like different front styles and finishes, homeowners can truly make the fireplace their own. The impressive viewing area, thanks to large glass doors, amplifies the beauty of the flames while also allowing for maximum heat output.

Thermal efficiency is a key characteristic of the LifeStyle 6000 series. With an impressive heating capacity, these units can effectively warm large spaces. Furthermore, they feature a range of BTU outputs, allowing users to select the model that best suits their heating needs. Models equipped with the IntelliFire Ignition system further enhance usability, providing reliable startup with the convenience of remote control operation.

Safety is also paramount in the design of the LifeStyle 6000 series. Each model comes with built-in safety features such as a glass safety barrier and optional automatic shut-off systems, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle 6000 series, including the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, stands out in the market for its combination of modern aesthetics, innovative heating technologies, and robust safety features. Whether enhancing a cozy living room or providing warmth in a spacious area, these fireplaces offer a stylish and efficient heating solution for contemporary homes.