Heat & Glo LifeStyle 6000G-IPILP, 6000G-LP owner manual Front View

Page 45

2

Figure 12.6 Front View

2

Figure 12.7 Top View

STEP 4. Log #2 (SRV2103-108):Place log #2 on top of the left side of log #1. The bottom of this log has a slot in it that goes over the tab molded into the top of log #1. The left end sits behind the simulated ember cluster on the burner top.

3

Figure 12.8 Front View

3

Figure 12.9 Top View

STEP 5. Log #3 (SRV2103-110):Place log #3 on top of the burner surface in front of the hump. The bottom of the log has a square groove cut through it. The groove sits over the second grate tine from the left. Slide it back against the hump.

4

Figure 12. 10 Front View

4

Figure 12. 11 Top View

STEP 6. Log #4 (SRV2103-109):Place log #4 on top of the right side of log #1. The bottom of this log has a slot in it that goes over the tab molded into the top of log #1. The other end of the log rests on the grate, against the second tine from the right.

5

Figure 12.12 Front View

5

Figure 12.13 Top View

STEP 7. Log #5 (SRV2103-111):Place log #5 in front of log #3 the notch in the bottom of this log rests over the center tine on the grate. The log shouldn’t cover any ports.

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

45

Image 45
Contents Hot glass will cause burns What to do if you smell gasHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsInstallation to ensure maximum safety and benefit Getting StartedTools and Supplies Needed Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase ClearancesClearance to Combustibles To Ceiling Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsMinimum Maximum V1 Minimum H1 + H2 MaximumMin Max V2 Min H2 Max Top Vent Horizontal Termination Three ElbowsE a K R E Flue Restrictor InstructionsMaximum + V 2 Min H1+ H2 V1 + V2 Minimum H1+ H2 Maximum Top Vent Vertical TerminationH1 = 16 in mm Maximum Rear Vent Horizontal TerminationH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max H1 Maximum V1 Minimum H1+ H2 MaximumH1+ H2 Maximum V1 Minimum Rear Vent Vertical TerminationV1 Minimum H1+ H2+ H3 Maximum 10 ft Maximum Minimum + H 2 MaximumPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP SLP Vertical Penetration FramingInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentProceed to . C Securing and Leveling the Appliance Installing the Non-combustible BoardInstall the Optional HEAT-ZONE-GAS Kit Attach Vent to the Firebox Assembly Installing Vent Pipe DVP and SLP PipeAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Slip Sections Assemble Vent Sections SLP Pipe OnlyDisassemble Vent Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingSLP-FS Install RF4-8Install Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Fuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Intellifire Ignition System Wiring Recommendation for WireConnecting to the Appliance Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Standing Pilot Ignition System WiringJunction Box Installation Wall Switch Installation for Fan OptionalVAC to wall switch Facing Material FinishingFinish Door FIT Material See Maximum Thickness Finishing MaterialClean the Appliance Appliance SetupAccessories Ember PlacementLog #1 SRV2103-107 Positioning the Logs12 Front View Air Shutter Setting Glass AssemblyScreen Mesh Grilles and TrimBefore Lighting Appliance Operating InstructionsTurn off all electric power to the appliance Lighting Instructions IPIFinal inspection by Standing Pilot Ignition For Your Safety Read Before Lighting Lighting InstructionsFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System flame has been lit, flame Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters P 4 5 4 5 E lb o w Vent Components DiagramsDVP vent components Horizontal Termination CapRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2302 mm 13-3/4 13-7/8 352 mm 349 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Wall Shield Firestop ElbowRF4-8 Roof Flashing Ceiling Firestop SupportSupport Box-Black SnorkelPVK-80 AdapterLog Set Assembly Service PartsPart number list on following At Depot Service Parts List 6000G, 6000G-IPIStanding Pilot IPI IgnitionStocked Standing Pilot Valve Assembly6000G-IPI IPI Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

6000G-IPILP, 6000G-IPI, 6000G, 6000G-LP specifications

The Heat & Glo LifeStyle 6000 series offers a sophisticated solution for homeowners seeking both performance and style in their heating options. With models such as the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, this series combines innovative technologies with elegant design, making it a preferred choice for many.

One of the standout features of the LifeStyle 6000 series is its advanced heating technology. The units utilize Direct Vent technology, which ensures efficient combustion by drawing air from the outside for combustion and venting exhaust air outdoors. This not only enhances efficiency but also maintains a safe and comfortable indoor environment. Additionally, these models are designed with advanced burner systems that provide realistic flame effects and a warm ambiance, making them perfect for any living space.

The aesthetic appeal of the LifeStyle 6000 series cannot be overlooked. These fireplaces boast a contemporary design that seamlessly integrates into various architectural styles. With customizable options like different front styles and finishes, homeowners can truly make the fireplace their own. The impressive viewing area, thanks to large glass doors, amplifies the beauty of the flames while also allowing for maximum heat output.

Thermal efficiency is a key characteristic of the LifeStyle 6000 series. With an impressive heating capacity, these units can effectively warm large spaces. Furthermore, they feature a range of BTU outputs, allowing users to select the model that best suits their heating needs. Models equipped with the IntelliFire Ignition system further enhance usability, providing reliable startup with the convenience of remote control operation.

Safety is also paramount in the design of the LifeStyle 6000 series. Each model comes with built-in safety features such as a glass safety barrier and optional automatic shut-off systems, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle 6000 series, including the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, stands out in the market for its combination of modern aesthetics, innovative heating technologies, and robust safety features. Whether enhancing a cozy living room or providing warmth in a spacious area, these fireplaces offer a stylish and efficient heating solution for contemporary homes.