Heat & Glo LifeStyle 6000G-LP, 6000G-IPILP Junction Box Installation, VAC to wall switch

Page 40

E. Junction Box Installation

Remove the screw attaching the junction box/re- ceptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.4).

Pull the electrical wires from outside the appli- ance through this opening into the valve compart- ment.

Feed the necessary length of wire through the connector.

Make all necessary wire connections to the junc- tion box/receptacle and reassemble the junction box/receptacle to the outer shell.

Romex

Connector

14/2WG

WHTBLK

WHT

 

BLK

Copper

 

GRN wire

ground attached

to GRN screw with

inside box

GRN wire

 

Note: Do NOT wire 110

 

VAC to wall switch.

Figure 10.4 Junction Box Detail

F. Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall mounted switch for use with a fan (See Figure 10.5):

The power supply for the appliance must be brought into a switch box.

The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire.

At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown.

At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown.

Add a 1/4 inch insulated female con- nector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 inch male) as shown.

 

 

 

SWITCH

MINIMUM 14-3

AW G

 

 

WITH GROUND

 

 

 

 

 

Red

Black

 

 

Black

 

 

White

White

 

 

Green

Green

JUNCTION BOX

 

 

 

 

Red

Black White Green

 

 

 

 

POWER

 

 

 

SUPP LY WIRE S

 

 

 

SWITCH BOX

Red

 

 

 

Figure 10.5 Junction Box Wired to Wall Switch

 

40

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. M • 9/08

Image 40
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGetting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Framing and Clearances Selecting Appliance LocationClearances Constructing the Appliance ChaseClearance to Combustibles Mantel Projections To CeilingVent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal Termination One ElbowMinimum Maximum V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows Min Max V2 Min H2 MaxFlue Restrictor Instructions E a K R EMaximum + V 2 Min Top Vent Vertical Termination H1+ H2 V1 + V2 Minimum H1+ H2 MaximumRear Vent Horizontal Termination H1 = 16 in mm MaximumH1 Maximum V1 Minimum H1+ H2 Maximum H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 MaxRear Vent Vertical Termination H1+ H2 Maximum V1 MinimumMaximum Minimum + H 2 Maximum V1 Minimum H1+ H2+ H3 Maximum 10 ftVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Pipe DVP SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Top Vent Appliance PreparationProceed to . C Installing the Non-combustible Board Securing and Leveling the ApplianceInstall the Optional HEAT-ZONE-GAS Kit Installing Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe Sections DVP Pipe OnlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSInstall Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Ansi Z223.1 and CAN/CGA-B149 installation codes Install Horizontal Termination Cap DVP and SLP PipeRefer to of this manual Gas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Intellifire Ignition System WiringConnecting to the Appliance Optional Accessories RequirementsStanding Pilot Ignition System Wiring Intellifire Pilot Ignition IPI Wiring DiagramWall Switch Installation for Fan Optional Junction Box InstallationVAC to wall switch Finishing Facing MaterialFinishing Material Finish Door FIT Material See Maximum ThicknessAppliance Setup Clean the ApplianceAccessories Ember PlacementPositioning the Logs Log #1 SRV2103-10712 Front View Glass Assembly Air Shutter SettingScreen Mesh Grilles and TrimOperating Instructions Before Lighting ApplianceLighting Instructions IPI Turn off all electric power to the applianceFinal inspection by For Your Safety Read Before Lighting Lighting Instructions Standing Pilot IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System flame has been lit, flame Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsReference Materials Appliance Dimension DiagramLocation Inches Millimeters Vent Components Diagrams P 4 5 4 5 E lb o wHorizontal Termination Cap DVP vent components787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 Roof Flashing Multi-pak 13-3/4 11-7/8 349 mm302 mm 13-3/4 13-7/8 352 mm 349 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Elbow Wall Shield FirestopRF4-8 Roof Flashing Ceiling Firestop SupportSnorkel Support Box-BlackPVK-80 AdapterService Parts Log Set AssemblyPart number list on following Service Parts List 6000G, 6000G-IPI At DepotStanding Pilot IPI IgnitionStanding Pilot Valve Assembly StockedIPI Valve Assembly 6000G-IPICONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

6000G-IPILP, 6000G-IPI, 6000G, 6000G-LP specifications

The Heat & Glo LifeStyle 6000 series offers a sophisticated solution for homeowners seeking both performance and style in their heating options. With models such as the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, this series combines innovative technologies with elegant design, making it a preferred choice for many.

One of the standout features of the LifeStyle 6000 series is its advanced heating technology. The units utilize Direct Vent technology, which ensures efficient combustion by drawing air from the outside for combustion and venting exhaust air outdoors. This not only enhances efficiency but also maintains a safe and comfortable indoor environment. Additionally, these models are designed with advanced burner systems that provide realistic flame effects and a warm ambiance, making them perfect for any living space.

The aesthetic appeal of the LifeStyle 6000 series cannot be overlooked. These fireplaces boast a contemporary design that seamlessly integrates into various architectural styles. With customizable options like different front styles and finishes, homeowners can truly make the fireplace their own. The impressive viewing area, thanks to large glass doors, amplifies the beauty of the flames while also allowing for maximum heat output.

Thermal efficiency is a key characteristic of the LifeStyle 6000 series. With an impressive heating capacity, these units can effectively warm large spaces. Furthermore, they feature a range of BTU outputs, allowing users to select the model that best suits their heating needs. Models equipped with the IntelliFire Ignition system further enhance usability, providing reliable startup with the convenience of remote control operation.

Safety is also paramount in the design of the LifeStyle 6000 series. Each model comes with built-in safety features such as a glass safety barrier and optional automatic shut-off systems, ensuring peace of mind for users.

In summary, the Heat & Glo LifeStyle 6000 series, including the 6000G, 6000G-IPILP, 6000G-IPI, and 6000G-LP, stands out in the market for its combination of modern aesthetics, innovative heating technologies, and robust safety features. Whether enhancing a cozy living room or providing warmth in a spacious area, these fireplaces offer a stylish and efficient heating solution for contemporary homes.